Series 2 - T-3A cavity and T-5A cavity, Viton, cartridge seal kit
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The Series 2, two port cavity comes in two versions: the T-3A and the T-5A. The T-3A cavity is typically used in relief applications which require larger port areas, hence a deeper cavity. The T-5A cavity is typically used in flow control applications and utilizes a smaller port area. Since both cavities are Series 2, two port, they share common seal kits, but exclude the possibility of cartridge interchangeability between the two functions.
- The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series | 2 |
Cartridge Thread | 1"-14 UNS1"-14 UNS |
Valve Hex Size | 1 1/8 in.28,6 mm |
Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
Cavity | T-3A & T-5A |
Used With [ + ]
What models can this kit be used with?
- CNEC Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check
- CNFC Free flow nose to side check valve with bypass orifice
- CXED Free flow side to nose check valve
- CXFA Free flow nose to side check valve
- CXFHZ Free flow nose to side check valve with position switch
- DFDA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFDA8 2-way, poppet directional valve with integral T-8A control cavity - control 1-2
- DFDB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFDB8 2-way, poppet directional valve with integral T-8A control cavity - control 2-1
- FCDB Fixed-orifice pressure compensated flow control valve with reverse flow check
- FDCB Fully adjustable pressure compensated flow control valve with reverse flow check
- FLFA Filter
- FPFK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
- FQEA Fixed-orifice, flow fuse valve
- FXDA Fixed-orifice, pressure compensated flow control valve
- FXDA8 Ventable fixed-orifice, pressure compensated flow control valve with integral T-8A control cavity
- NCEB Fully adjustable needle valve with reverse flow check
- NCEC Fully adjustable needle valve with reverse flow check
- NFDC Fully adjustable needle valve
- NFDD Fully adjustable needle valve
- NQEB Air bleed and start-up valve
- RBAA Direct-acting relief valve - pilot capacity
- RBAB Air-controlled, direct-acting relief valve - pilot capacity
- RGFA Low-pressure-range, direct-acting relief valve
- RPGC Pilot-operated, balanced piston relief valve
- RPGC8 Pilot-operated, balanced piston relief main stage with integral T-8A control cavity
- RPGD Air-controlled, pilot-operated, balanced piston relief valve
- RPGE Fast-acting, pilot-operated, balanced piston relief valve
- RQGB Kick-down, pilot-operated, balanced piston relief valve
- SCEB Atmospherically referenced, direct-acting sequence valve with reverse flow check
- XCCA All ports blocked cavity plug
- XCOA All ports open cavity plug
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
- During 1985, SUN made a running change of all external seals on Series 2 cartridges (1-1/8 in. (28,6 mm) hex, 1-14 thd). The seals were changed from 3/32 in. (2,62 mm) c/s to 1/16 in (1,7/8 mm) c/s o-rings and backup rings.
- Use the kit which contains the same size (c/s) seals as those used on the cartridge being repaired. Do not change cartridge o-ring c/s sizes.
Additional Resources [ + ]
Technical Information