Electro-proporcional 3-vías control de caudal válvula , alimentación regulada (740 Series)

Capacidad: 6 gpm23 L/min. | Cavidad: T-11A
FMDG : Electro-proporcional  3-vías control de caudal válvula , alimentación regulada  (740 Series)
Technical Features [ + ]

This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control. Flow in the 2 to 3 direction is not proportional.

  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • All ports will accept 5000 psi (350 bar).
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • This valve can be used with both the 740 Series high-power coils and 747 Series hazardous location coils.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-11A
Series 1
Capacity 6 gpm23 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi30 cc/min.@70 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .63 in.16 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Seal and nut kit - Coil Viton: 990740006
Seal kit - Cartridge Buna: 990411007
Seal kit - Cartridge Viton: 990411006
Proportional Performance Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
Hysteresis (with dither) <4%<4%
Hysteresis with DC input <8%<8%
Linearity (with dither) <2%<2%
Repeatability (with dither) <2%<2%
Recommended dither frequency 140 Hz140 Hz
Deadband, nominal (as a percentage of input) 60%60%
Performance Curves [ + ]
FAQs [ + ]

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

The valve acts as a 2 port restrictive flow control.

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Additional Resources [ + ]
Coil Information [ + ]

No coil selected.