Caudal libre de nariz al lado anti-retorno válvula con indicador de posición

Capacidad: 30 gpm120 L/min. | Cavidad: T-5A
CXFHZ : Caudal libre de nariz al lado  anti-retorno válvula  con indicador de posición
Technical Features [ + ]

Free-flow, nose-to-side check valves are on/off circuit components that allow free flow from the inlet (port 1) to the outlet (port 2) and block flow in the opposite direction.

This valve incorporates a position switch to provide confirmation that the valve is in the transition position or seated (closed).

  • The position switch in this valve provides confirmation that the valve is closed.
  • This cartridge is supplied as a sealed, factory set unit and is not field serviceable. Any tampering will violate the product warranty.
  • When torquing this cartridge into its cavity, a crow's foot wrench or similar will be required since the position switch precludes the use of a deep socket wrench.
  • All ports will accept 5000 psi (350 bar).
  • An optional protective cover, with mounting hardware included, may be ordered separately. See kit number: 991-043.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-5A
Series 2
Capacity 30 gpm120 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Transition leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi30 cc/min.@70 bar
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Seal kit - Cartridge Buna: 990203007
Seal kit - Cartridge Viton: 990203006
Switch Specifications [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
Supply Voltage 20-30 VDC20-30 VDC
Operating Temperature Range -25 to 80 °C-25 to 80 °C
Vibration ≥ 50g, 0-500 impulses/sec≥ 50g, 0-500 impulses/sec
Shock >50 g, 1ms>50 g, 1ms
Reverse Polarity Protection YesYes
Maximum Output Load ≤ 400 mA, Duty Ratio 100%≤ 400 mA, Duty Ratio 100%
Short Circuit Protection Yes, Load Short UnlimitedYes, Load Short Unlimited
Turn On Time ≤ 25 ms≤ 25 ms
Hysteresis ≤ .002 in.≤ .002 in.
Thermal Shift - 0 to 80 °C ≤ ± .004 in.0,1 mm
EMC DIN EN 61000-6-1/2/3/4DIN EN 61000-6-1/2/3/4
conector M12 X 1 (4) PinM12 X 1 (4) Pin
Connector Environment Rating IP65IP65
FAQs [ + ]

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Additional Resources [ + ]