Solenoid-operated, rapid advance and feed 流量控制 安装组件

Function

Function for X4CN: Meter in A Normally Open
Meter in A Normally Open
Function for X4CN: Meter in B Normally Open
Meter in B Normally Open
Function for X4CN: Meter out A Normally Open
Meter out A Normally Open
Function for X4CN: Meter out B Normally Open
Meter out B Normally Open
技术特性 [ + ]

This assembly consists of a needle valve which is a fully-adjustable orifice used to regulate flow. It is infinitely adjustable from fully closed up to the maximum orifice diameter. It is not pressure-compensated. It may be used as flow controls or as shutoff valves. The rapid or feed rate is selected by a solenoid operated (normally open or closed) 2-way, 2-position valve.

  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
  • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
  • 现在可适用于FLeX系列电磁阀。见配置部分,电磁选项中。
技术数据 [ + ]
阀块类型 叠加式叠加式
表面 ISO 03ISO 03
通流能力 15 gpm60 L/min.
阀块特性 meter in A or B, meter out A or Bmeter in A or B, meter out A or B
Stack Height 1.75 in.44,5 mm
带密封板(见说明)
控制流量范围 0 - 7 gpm0 - 7 gpm
常见问题 [ + ]

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

备注 [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
额外来源 [ + ]
Coil Information [ + ]

No coil selected.