直动式, 减压/溢流阀 带开式过渡位
直动式减压阀将进口(口2)高压主油路压力调节减至口1所需的减压压力。此类阀的阻尼结构实现对高的减压力的稳定调节。此阀在减压与溢流模式之间的过渡位是打开的。这种过渡位置使阀具备良好的压力控制与动态响应性能。
- 减压到溢流为微开的过渡位,因此此阀具有良好的压力控制性能,油液的消耗速率为0.1 gpm(0,4 L/分钟。)。高的先导控制流量只对闭死应用有影响。
- 配置EPDM密封圈的插装阀可用在磷酸酯液压油系统。暴露在石油基液压油或润滑油脂中会损坏密封圈。
- 从减压压力口(口1)到进口(口2)的反向液流可能导致主阀芯关闭。如果油路中需要反向自由流,可以考虑在油路中加入单向阀。
- 所有弹簧范围都用5000 psi (350 bar)进口压力来测试。
- 直动式作用的概念在受污染系统中可提供更高的可靠性操作,特别是在闭死情况下。
- 直动式版本比相应先导式操作类型具有更好的动态响应。
- 口3处的压力直接以1:1的比例增加到阀的设定值上,且压力不能超出5000 psi(350 bar)。
- 技术数据中标定的口3泄漏发生在进口压力为2000 psi (140 bar) 且阀设定在中间范围时。此泄漏直接与压降成正比并与油液粘度成反比。
- 所有3口减压阀和减压/溢流阀在尺寸上可互换(如:给定的外形结构尺寸阀拥有相同的流道,相同的插孔)。考虑安装配置时,减压/溢流阀的回油路(口3)最好具有公称流量能力。
- 利用Sun浮动结构减少由于过量安装扭矩或插孔/插装阀加工误差带来的内部零件粘结的可能性。
插孔 | T-11A |
系列 | 1 |
通流能力 | 10 gpm40 L/min. |
最大操作压力 | 5000 psi350 bar |
工厂默认的设定值 | 0.25 gpm0.25 gpm |
110 SUS (24 cSt)下的最大泄漏 | 20 in³/min.330 cc/min. |
调节 - 从最小设定到最大设定的顺时针圈数 | 55 |
阀头部安装六角尺寸 | 7/8 in.22,2 mm |
阀安装扭矩 | 30 - 35 lbf ft41 - 47 Nm |
调节螺栓的内六角尺寸 | 5/32 in.4 mm |
锁紧螺母六角尺寸 | 9/16 in.15 mm |
锁紧螺母力矩 | 80 - 90 lbf in.9 - 10 Nm |
型号重量 | .30 lb0,15 kg |
Seal kit - Cartridge | Buna: 990011007 |
Seal kit - Cartridge | EPDM: 990011014 |
Seal kit - Cartridge | Polyurethane: 990011002 |
Seal kit - Cartridge | Viton: 990011006 |
设置压力的误差在产品的性能参数页中都有详细说明,您可以通过点击可选产品网页中的更多产品信息到达产品性能参数页面。
Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.
Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.
No. A reducing/relieving valve throttles a supply of oil to maintain a set pressure in a secondary circuit. The valve is open until the secondary or downstream pressure rises to the setting of the valve at which time it starts to close to limit the pressure. If the secondary or downstream pressure is caused to go above the setting, the valve shifts into relieving mode and throttles the secondary circuit back to tank to prevent over-pressure. At no time can the valve connect the supply to tank.
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.
2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.
When in doubt, use a reverse flow check.
- 对于采用O控制(旋钮调节,带面板锁)的系列1插装阀,面板上需要留一个直径0.75 in. (19 mm)的孔。
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun FLeX™系列电磁阀&线圈
- Sun推出抗腐蚀产品解决方案
- Sun Cartridges with EPDM Seals
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Another Optimized Solution from Sun Hydraulics!
- Sun’s Cartridge Symbol Library
- Sun插装阀插孔 (551.8 KB)
- 减压阀和溢流型减压阀 (575.89 KB)