固定节流口, 旁通/限流, 优先, 流量控制阀
旁通/节流,固定节流口,优先流量控制阀接受口1的输入流量,并用来满足口3的优先流量。如果输入流量超出优先流量需求,多余的流量经口2旁通流出。旁通流量可用于次级油路。
- 客户必须指定一个流量等级。出厂流量设定值在指定设定值的+/- 10%范围内。
- 口3处的最大压力应降限制在3000 psi (210 bar)以内。
- 可调控制选项可以使阀在出厂预设流量的+/- 22%范围内调节。可对调节螺杆进行+/- 3圈调整。旋进(顺时针)螺杆可增加流量。
- 优先流量和旁路流量在系统压力范围内保持稳定。
- 不管输入流量如何变化,优先流量保持稳定。
- 在满足优先流量之前,无法使用旁路流量。
- 旁通口(口2)压力可以超出优先口(口3)压力。
- 锐边节流口设计可有效减少因粘度变化引起的流量波动。
- 利用Sun浮动结构减少由于过量安装扭矩或插孔/插装阀加工误差带来的内部零件粘结的可能性。
插孔 | T-17A |
系列 | 3 |
通流能力 | 25 gpm95 L/min. |
最大操作压力 | 5000 psi350 bar |
最大输入流量 | 60 gpm240 L/min. |
阀头部安装六角尺寸 | 1 1/4 in.31,8 mm |
阀安装扭矩 | 150 - 160 lbf ft203 - 217 Nm |
调节螺栓的内六角尺寸 | 5/32 in.4 mm |
锁紧螺母六角尺寸 | 9/16 in.15 mm |
锁紧螺母力矩 | 80 - 90 lbf in.9 - 10 Nm |
型号重量 | 1.25 lb0,60 kg |
Seal kit - Cartridge | Buna: 990017007 |
Seal kit - Cartridge | Polyurethane: 990017002 |
Seal kit - Cartridge | Viton: 990017006 |
All flow is blocked, hence the term priority. The priority flow has to be satisfied.
The valve acts as a 2 port restrictive flow control.
The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.
We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.
I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.
- Sun推出抗腐蚀产品解决方案
- Sun FLeX™系列电磁阀&线圈
- Check Valves, Flow Control and Priority Flow Control Valves Technical Tips
- Another Optimized Solution from Sun Hydraulics!
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun’s Cartridge Symbol Library
- Sun插装阀插孔 (551.8 KB)
- 单向阀 节流阀 优先节流阀 (553.02 KB)
- Check, Flow Control, and Priority Flow Control Valves (537.44 KB)