Free flow nose to side check valve with position switch
Free-flow, nose-to-side check valves are on/off circuit components that allow free flow from the inlet (port 1) to the outlet (port 2) and block flow in the opposite direction.
This valve incorporates a position switch to provide confirmation that the valve is in the transition position or seated (closed).
- The position switch in this valve provides confirmation that the valve is closed.
- This cartridge is supplied as a sealed, factory set unit and is not field serviceable. Any tampering will violate the product warranty.
- When torquing this cartridge into its cavity, a crow's foot wrench or similar will be required since the position switch precludes the use of a deep socket wrench.
- All ports will accept 5000 psi (350 bar).
- An optional protective cover, with mounting hardware included, may be ordered separately. See kit number: 991-043.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cavity | T-16A |
Series | 3 |
Capacity | 60 gpm240 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Maximum Valve Leakage at 110 SUS (24 cSt) | 1 drops/min.0,07 cc/min. |
Transition leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
Valve Hex Size | 1 1/4 in.31,8 mm |
Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
Seal kit - Cartridge | Buna: 990016007 |
Seal kit - Cartridge | Polyurethane: 990016002 |
Seal kit - Cartridge | Viton: 990016006 |
Supply Voltage | 20-30 VDC20-30 VDC |
Operating Temperature Range | -25 to 80 °C-25 to 80 °C |
Vibration | ≥ 50g, 0-500 impulses/sec≥ 50g, 0-500 impulses/sec |
Shock | >50 g, 1ms>50 g, 1ms |
Reverse Polarity Protection | YesYes |
Maximum Output Load | ≤ 400 mA, Duty Ratio 100%≤ 400 mA, Duty Ratio 100% |
Short Circuit Protection | Yes, Load Short UnlimitedYes, Load Short Unlimited |
Turn On Time | ≤ 25 ms≤ 25 ms |
Hysteresis | ≤ .002 in.≤ .002 in. |
Thermal Shift - 0 to 80 °C ≤ ± | .004 in.0,1 mm |
EMC | DIN EN 61000-6-1/2/3/4DIN EN 61000-6-1/2/3/4 |
Connector | M12 X 1 (4) PinM12 X 1 (4) Pin |
Connector Environment Rating | IP65IP65 |
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- CavitySaver multi-function valves deliver single-cartridge solutions
- Pilot Controlled Directional Cartridges Technical Tips
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Check Valves, Flow Control and Priority Flow Control Valves Technical Tips
- Sun's New FLeX Series Solenoid Valves & Coils
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- New FLeX Series Solenoid-Operated Directional Valves
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334 (343.9 KB)
- Performance Data
- Cartridges: Materials of Construction
- Cavity Information (S-171) and Tooling
- Fluid Recommendations: Oil Viscosity, Cleanliness & Temperature
- Sun's Floating Style Screw-In Cartridge (1.06 MB)
- CE Declaration of Conformity - XMD 12-2017 (133.69 KB)