The example shows circuits with proportional valves for lifting and lowering a single-acting cylinder.
- 2-way, solenoid-operated poppet valve: DT*A
- Pilot-operated proportional throttle: FP*K
- Proportional flow control : FP*C
- 2 stage solenoid-operated poppet valve: DF*A
- 3-way solenoid-operated directional valve: DM*A
- Logic valve: DK*C
Benefits of this circuit arrangement
- Fig.1 shows two 2/2 way solenoid valves DT*A to hold, lift or lower a cylinder. A proportional throttle valve FP*C (0- 10 gpm) controls the lifting or lowering speeds of the cylinder.
- Fig. 2 has the same functionality as the above, but for higher flow rates. The logic valve DK*C (piloted by a 2/3 way DM*A) and a 2/2 way solenoid poppet valve DF*A hold, lift or lower the cylinder.
- The pilot operated proportional throttle valve FP*K with a flow rate of 0 - 60 gpm (@ 200 psi 200 psi P) controls the lifting or lowering speeds of the cylinder.