« Back to Library PDF herunterladen

Cylinders - Lifting/Lowering, Single-Acting (2)

The example shows circuits with proportional valves for lifting and lowering a single-acting cylinder.

  • 2-way, solenoid-operated poppet valve:         DT*A 
  • Pilot-operated proportional throttle:                FP*K 
  • Proportional flow control :                                FP*C 
  • 2 stage solenoid-operated poppet valve:          DF*A       
  • 3-way solenoid-operated directional valve:      DM*A
  • Logic valve:                                                        DK*C

Benefits of this circuit arrangement

  • Fig.1 shows two 2/2 way solenoid valves DT*A to hold, lift or lower a cylinder. A proportional throttle valve FP*C  (0- 10 gpm) controls the lifting or lowering speeds of the cylinder.
  • Fig. 2 has the same functionality as the above, but for higher flow rates. The logic valve DK*C (piloted by a 2/3 way DM*A) and a 2/2 way solenoid poppet valve DF*A hold, lift or lower the cylinder. 
  • The pilot operated proportional throttle valve FP*K with a flow rate of 0 - 60 gpm (@ 200 psi 200 psi P) controls the lifting or lowering speeds of the cylinder.