3-vías, cambio suave , direccional, operada por solenoide carrete válvula - capacidad de pilotaje (740 Series)
Capacidad: .25 gpm1 L/min. |
Cavidad: T-9A
Technical Features [ + ]
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool pilot valve used to pilot other full-flow valves. The valve is normally open between port 1 and port 2 or port 1 and port 3 and all flow paths are bidirectional.
This valve is designed to be used with 740 and 747 Series coils.
- The soft shift cartridge is interchangeable with the standard cartridge, however, the performance limits are lower.
- The soft shift feature can reduce shock due to valve actuation but should not be counted upon in applications where timing is critical. If you need accurate ramping or timing control, consider Sun's electro-proportional valves.
- The soft shift feature results in an increase in response time over Sun's standard solenoid. Response time is dependent on flow, pressure, coil voltage, oil viscosity and ambient temperature.
- For consistent soft shift performance, port 1 should be at a positive pressure.
- The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
- This valve is direct actuated and requires no minimum hydraulic pressure for operation.
- Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This cartridge utilizes 740 Series low-power and high-power coils, and 747 Series hazardous location coils for both Normally Open and Normally Closed configurations.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
- A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
- Coils can be mounted on the tube in either direction.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad | T-9A |
Series | P |
Capacity | .25 gpm1 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Manual Override Force Requirement | 10 lbs/1000 psi @ Port 166 N/100 bar @ Port 1 |
Manual Override Stroke | .10 in.2,5 mm |
Solenoid Tube Diameter | .63 in.16 mm |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 20 - 25 lbf ft27 - 33 Nm |
Seal kit - Cartridge | Buna: 990009007 |
Seal kit - Cartridge | Polyurethane: 990009002 |
Seal kit - Cartridge | Viton: 990009006 |
Performance Curves [ + ]
FAQs [ + ]
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
- Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
Additional Resources [ + ]
Realces
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Solenoid Operated Directional Valves Technical Tips
- QuickDesign con SmartConnect Ofrece una Herramienta para Construir Esquemáticos
- Nuevas válvulas direccionales accionadas por solenoide de la serie FLeX
- Pilot Controlled Directional Cartridges Technical Tips
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Válvulas y bobinas a solenoides de la serie Sun FLeX
- Sun Expands Corrosion-Resistant Solutions
- Nuevas válvulas direccionales de bloqueo por asiento de 3 vías de la serie FLeX ™
- Pilot-to-Shift Directional Valves and Proportional Throttles
- Manually Operated Directional Valves
- Sun Cartridges with EPDM Seals
Technical Tips
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Solenoid Coils for Switching and Proportional Valves (975.2 KB)
- Solenoid Operated Directional Valves (1.01 MB)
Technical Information
Coil Information [ + ]
No coil selected.