2-vías , manually operated, carrete direccional válvula - capacidad de pilotaje

Capacidad: .25 gpm1 L/min. | Cavidad: T-8A
DAAM : 2-vías , manually operated, carrete direccional válvula  - capacidad de pilotaje
Technical Features [ + ]

These pilot-stage, directional, 2-position, 2-way valves are manually operated cartridges and are available in either a normally open or normally closed configuration. These cartridges are designed for pilot flow applications and utilize Sun's T-8A cavity so they can be used in conjunction with Sun's pilot-operated, main-stage valves. Manual operation is achieved via Sun's Twist/Lock manual override mechanism and is designed for intermittent (infrequent) use only.

  • This valve is designed for intermittent use such as a manual override. The manual control assembly has a mechanical life expectancy of about 10,000 cycles.
  • The manual control assembly can be easily replaced in the field without removing the cartridge from the manifold or main stage element.
  • The momentary/twist control option "T" allows the operator to momentarily shift the valve by twisting the knob clockwise and releasing. Once released, the valve returns to its normal position.
  • The detent/lock control option "L" allows the operator to shift the valve into a mechanically detented position by twisting the knob counter-clockwise. This detented position will be maintained until the operator twists the knob clockwise and allows the valve to return to its normal position.
  • The dual-operation control option "D" allows the operator to either shift the valve momentarily by twisting the knob clockwise or shift it into a mechanically detented postion by twisting counter-clockwise.
  • The control on this valve is meant to be operated by a person's hand. The control should not be modified, for instance fastening a lever to the knob. Under no circumstances should the control be operated by other mechanical devices.
  • Utilizes the Sun T-8A 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage pilot or vent-to-operate cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-position, 2-way pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • The preferred flow path through the valve is port 2 to port 1.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-8A
Series P
Capacity .25 gpm1 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 10 drops/min.@5000 psi0,7 cc/min.@350 bar
Operating Torque 10 lbf in.1,2 Nm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 20 - 25 lbf ft27 - 33 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Buna: 990108007
Seal kit - Cartridge Viton: 990108006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.