Operación doble de girar/bloquear, activador manual juego de control, control D
The Twist/Lock manual override is a rotary, hand-actuated device for use on Sun's full flow solenoid valves and certain Series P models. The hand knob is constructed of a reinforced plastic for durability, heat resistance and stability in varying environmental conditions and is suitable for operation with a gloved hand. The override assembly incorporates a sealed-construction design thereby preventing the introduction of debris and other damaging contamination. Once installed on a Sun solenoid valve, the override feature allows the operator to manually shift the de-energized valve. Solenoid cartridges may be ordered in this configuration by specifying a "D" control in the cartridge model number. Sun kits for field conversion are also available. Please note that valves with the Twist/Lock manual override are not suitable for load holding applications.
- The dual operation override option "D" allows the operator to either shift momentarily by turning clockwise or place it in the detent postion by turning counter-clockwise.
- The manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
Material | Black plastic and aluminumBlack plastic and aluminum |
Description | Dual (Twist/Lock) Operation (Option D)Dual (Twist/Lock) Operation (Option D) |
Operating Torque | 10 lbf in.1,2 Nm |
What models can this kit be used with?
- DAAL2-vías , direccional, operada por solenoide carrete válvula - capacidad de pilotaje
- DAAM 2-vías , manually operated, carrete direccional válvula - capacidad de pilotaje
- DBAL3-vías, direccional, operada por solenoide carrete válvula - capacidad de pilotaje
- DBAM 3-vías, manually operated, carrete direccional válvula - capacidad de pilotaje
- DFCA2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
- DFCB2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
- DFDA2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
- DFDB2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
- DFEA2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
- DFEB2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
- DFFA2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
- DFFB2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
- DLDA2-vías , direccional, operada por solenoide carrete válvula
- DLDM 2-vías , manually operated, direccional carrete válvula
- DMDA 3-vías, direccional, operada por solenoide carrete válvula
- DMDM 3-vías, manually operated, direccional carrete válvula
- DNCA 4-vías, 2-posiciones , direccional, operada por solenoide carrete válvula con transición cerrada
- DNDA 4-vías, 2-posiciones , direccional, operada por solenoide carrete válvula
- DNDM 4-vías, manually operated, direccional carrete válvula
- DNDY 2-posiciones , 6-vías, direccional, operada por solenoide carrete válvula
- DNDYS 2-posiciones , 6-vías, cambio suave , direccional, operada por solenoide carrete válvula
- DTCA2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula con superponer
- DTCM 2-vías , manually operated, direccional disco válvula con superponer
- DTDA2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula
- DTDM 2-vías , manually operated, direccional disco válvula
- DWDA3-vías, acción-directa , direccional, operada por solenoide disco válvula
- DWDM 3-vías, manually operated, direccional disco válvula
- FMDA Electro-proporcional 3-vías control de caudal válvula , alimentación regulada
- FMDB Electro-proporcional 3-vías control de caudal válvula , alimentación regulada
- FPCC Electro-proporcional control de caudal válvula - normalmente cerrado
- FPCH Electro-proporcional control de caudal válvula - normalmente abierto
- HDDA 2-vías , direccional, operada por solenoide disco válvula - después del anti-retorno
- Ensure o-ring is installed in bottom of the manual override assembly.
- Remove existing coil nut from end of solenoid tube.
- Thread the manual override assy on to the end of the solenoid tube. Point coil connector in desired position before hand tightening the manual override assy.
- Note: Thread lock may be used if anticipated conditions warrant.