- Vented counterbalance valve: CW*K
Benefits of this circuit arrangement:
- The circuit compensates for the leakage in the motor upstream, allowing both motors to deliver the same torque.
- The counterbalance valve is used as a relief valve. Port 4 of the valve connected to port 2 the downstream pressure is additive to the setting with a factor of 2x. With a low setting of the CW*K, the pressure on port 1 is 2x the pressure on port 2: The valve will open when pressure between both motors falls below the pressure upstream the motor. Ensuring the inlet pressure of motor 1 is double the pressure between motor 1 & 2 guarantees the torque is evenly spread.
For Sun technical support, contact Bernd Zaehe.