Series 1 - T-21A cavity, Viton, cartridge seal kit
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series | 1 |
Cartridge Thread | M20M20 |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Cavity | T-21A |
Cartridge Seal Installation Variations [ + ]
Cartridge Assignments | Models: CVCV, CWBG, CWBK, CWCA, CWCG, CWCK, CWCL, DKDP, DKDR, DKDS, DODP, DODR, DODS, DPBM, DPBN, DPBO, DVBM, DVBN, DVBO, DVBP, FVCA, HVCA, LKDS, LODS, LRDS, MWCA, MWCB, MWCG, XMCA, XMBA, RVCD, Views: A,B,C,DModels: CVCV, CWBG, CWBK, CWCA, CWCG, CWCK, CWCL, DKDP, DKDR, DKDS, DODP, DODR, DODS, DPBM, DPBN, DPBO, DVBM, DVBN, DVBO, DVBP, FVCA, HVCA, LKDS, LODS, LRDS, MWCA, MWCB, MWCG, XMCA, XMBA, RVCD, Views: A,B,C,D |
Cartridge Assignments | Models: DRBO, DRBR, PVDB, QCDB, QCDD, DRBN, PVDA, QCDA, QCDC, PSDB, DRBM, DRBP, PSDL, PSDP, PSDT, PVDH, QCDE, FKBA, FKBB, FKCA, FKCB, LPDS, PVDD, PVDC, Views: A,B,C,EModels: DRBO, DRBR, PVDB, QCDB, QCDD, DRBN, PVDA, QCDA, QCDC, PSDB, DRBM, DRBP, PSDL, PSDP, PSDT, PVDH, QCDE, FKBA, FKBB, FKCA, FKCB, LPDS, PVDD, PVDC, Views: A,B,C,E |
Cartridge Assignments | Models: XMOA, Views: A,B,CModels: XMOA, Views: A,B,C |
Cartridge Assignments | Models: XMOB, View: AModels: XMOB, View: A |
Used With [ + ]
What models can this kit be used with?
- CVCV Vented pilot-to-open check valve
- CWCA 3:1 pilot ratio, vented counterbalance valve
- CWCG 5:1 pilot ratio, vented counterbalance valve
- CWCK 1:1 pilot ratio, vented counterbalance valve
- CWCL 2:1 pilot ratio, vented counterbalance valve
- DKDP Normally closed, balanced poppet, logic element - pressure adjustable
- DKDR Normally closed, balanced poppet, logic element - vent-to-open
- DKDR8 Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open
- DKDS Normally closed, balanced poppet, logic element - pilot-to-open
- DODP Normally open, balanced poppet, logic element - pressure adjustable
- DODR Normally open, balanced poppet, logic element - vent-to-close
- DODR8 Normally open, balanced poppet, logic element with integral T-8A control cavity - vent-to-close
- DODS Normally open, balanced poppet, logic element - pilot-to-close
- DPBM 2-way, pilot-operated, directional valve with drain to port 4 - normally open
- DPBN 2-way, pilot-operated, directional valve with drain to port 4 - normally closed
- DPBO 3-way, pilot-operated, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
- DPBP 3-way, pilot-operated, directional valve with drain to port 4 (1 to 2 open, 3 blocked)
- DRAX 2-way, pilot-to-shift directional valve with drain to port 4 - normally closed
- DRAY 2-way, pilot-to-shift directional valve with drain to port 4 - normally open
- DRBM 2-way, direct-acting, directional valve with drain to port 4 - normally open
- DRBMX 2-way, direct-acting, fixed setting, directional valve with drain to port 4 - normally open
- DRBN 3-way, direct-acting, directional valve with drain to port 4 - normally closed
- DRBNX 2-way, direct-acting, fixed setting, directional valve with drain to port 4 - normally closed
- DRBO 3-way, direct-acting, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
- DRBOX 3-way, direct-acting, fixed setting, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
- DRBP 3-way, direct-acting, directional valve with drain to port 4 (1 to 2 open, 3 blocked)
- DRBPX 3-way, direct-acting, fixed setting, directional valve with drain to port 4 (1 to 2 open, 3 blocked)
- DRBR 3-way, direct-acting, directional valve with drain to port 4 (3 to 4 open, port 2 blocked)
- DRBRX 3-way, direct-acting, fixed setting, directional valve with drain to port 4 (3 to 4 open, port 2 blocked)
- DVBM 2-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity - normally open
- DVBN 2-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity - normally closed
- DVBO 3-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity (1 blocked, 2 to 3 open)
- DVBP 3-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity (1 to 2 open, 3 blocked)
- FKBA 2-way, pilot-shifted, proportional throttle
- FKBB 2-way, pilot-shifted, proportional throttle with bleed down
- FKCA 2-way, pilot-shifted, proportional throttle, high capacity
- FKCB 2-way, pilot-shifted, proportional throttle with bleed down, high capacity
- FVCA Ventable, fixed-orifice, bypass/restrictive, priority flow control valve
- FVCA8 Ventable, fixed-orifice, bypass/restrictive, priority flow control valve with integral T-8A control cavity
- HVCA Ventable, pilot-operated, balanced piston relief valve - before check
- HVCA8 Ventable, pilot-operated, balanced piston relief main stage with integral T-8A control cavity - before check
- LPDS Normally open modulating element with shuttle
- LRDS Normally closed modulating element with shuttle
- PSDB Direct-acting, pressure reducing/relieving valve with drain to port 4
- PSDL Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4
- PSDP Electro-proportional, direct-acting, pressure reducing/relieving valve with drain to port 4
- PSDT Direct-acting, pressure reducing/relieving main stage piloted from port 4
- PVDA Pilot-operated, pressure reducing/relieving valve with drain to port 4
- PVDA8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity and drain to port 4
- PVDB Ventable, pilot-operated, pressure reducing/relieving valve
- PVDD Ventable, pilot-operated, pressure reducing/relieving valve with drilled piston orifice
- QCDA 15%, accumulator sense, pump unload valve with check - pilot capacity
- QCDB 20%, accumulator sense, pump unload valve with check - pilot capacity
- QCDC 30%, accumulator sense, pump unload valve with check - pilot capacity
- QCDD 50%, accumulator sense, pump unload valve with check - pilot capacity
- RVCD Ventable, pilot-operated, balanced piston relief valve with drain to port 4
- RVCD8 Ventable, pilot-operated, balanced piston relief main stage with integral T-8A control cavity and drain to port 4
- XMBA Port 1 to 3 open, ports 2 and 4 blocked, cavity plug
- XMCA All ports blocked cavity plug
- XMOA Ports 3 and 4 or port 5 and 6 blocked, all other ports open cavity plug
- XMOB All ports open cavity plug
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- See installation variations for models associated with alternative installation views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]
Technical Information