Series 2 - T-2A cavity, Polyurethane cartridge seal kit
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
- Polyurethane seals have a higher tensile strength, are more abrasion/extrusion resistant, and are well suited for high cycle and high pressure applications.
Cartridge Installation Data [ + ]
Series | 2 |
Cartridge Thread | 1"-14 UNS1"-14 UNS |
Valve Hex Size | 1 1/8 in.28,6 mm |
Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
Cavity | T-2A |
Used With [ + ]
What models can this kit be used with?
- CBDA 3:1 pilot ratio, restrictive counterbalance valve
- CBDAX Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve
- CBDB 1.5:1 pilot ratio, semi-restrictive counterbalance valve
- CBDBX Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve
- CBDC 3:1 pilot ratio, semi-restrictive counterbalance valve
- CBDCX Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve
- CBDD 4.5:1 pilot ratio, semi-restrictive counterbalance valve
- CBDDX Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve
- CBDG 4.5:1 pilot ratio, restrictive counterbalance valve
- CBDGX Fixed setting, 4.5:1 pilot ratio, restrictive counterbalance valve
- CBDHX Fixed setting, 10:1 pilot ratio, restrictive counterbalance valve
- CBDL 2.3:1 pilot ratio, semi-restrictive counterbalance valve
- CBEA 3:1 pilot ratio, standard capacity counterbalance valve
- CBEAX Fixed setting, 3:1 pilot ratio, standard capacity counterbalance valve
- CBEB 1.5:1 pilot ratio, standard capacity counterbalance valve
- CBEG 4.5:1 pilot ratio, standard capacity counterbalance valve
- CBEH 10:1 pilot ratio, standard capacity counterbalance valve
- CBEL 2.3:1 pilot ratio, standard capacity counterbalance valve
- CBEY 2:1 pilot ratio, standard capacity counterbalance valve
- CKEB Pilot-to-open check valve with standard pilot
- CKED Pilot-to-open check valve with sealed pilot
- CKEV Vented pilot-to-open check valve - atmospherically referenced
- CNED Free flow side to nose check valve with bypass orifice and port 3 blocked
- CNEE Pilot-to-open check valve with bypass orifice
- CNFE Pilot-to-close check valve with bypass orifice
- COFA Pilot-to-close check valve
- COFO 120:1 ratio, pilot-to-close check valve
- CXEE Free flow side to nose check valve with port 3 blocked
- CXFC Free flow nose to side check valve with port 3 blocked
- DKFC Normally closed, balanced poppet, logic element - pilot-to-open
- DKFD Normally closed, balanced poppet, logic element - vent-to-open
- DOFC Normally open, balanced poppet, logic element - pilot-to-close
- DOFD Normally open, balanced poppet, logic element - vent-to-close
- DPCA 2-way, pilot-operated, directional valve with internal drain to port 3 - normally open
- DPCB 2-way, pilot-operated, directional valve with internal drain to port 3 - normally closed
- DPCC 3-way, pilot-operated, directional valve with internal drain to port 3 (1 blocked, 2 to 3 open)
- DPCD 3-way, pilot-operated, directional valve with internal drain to port 3 (1 to 2 open, 3 blocked)
- DRCC 3-way, direct-acting, directional valve with internal drain to port 3 (1 blocked, 2 to 3 open)
- DVCA 2-way, vent-to-operate, directional valve with internal drain to port 3 and integral T-8A control cavity - normally open
- DVCB 2-way, vent-to-operate, directional valve with internal drain to port 3 and integral T-8A control cavity - normally closed
- DVCC 3-way, vent-to-operate, directional valve with internal drain to port 3 and integral T-8A control cavity (1 blocked, 2 to 3 open)
- DVCD 3-way, vent-to-operate, directional valve with internal drain to port 3 and integral T-8A control cavity (1 to 2 open, 3 blocked)
- FRDA Fixed-orifice, bypass/restrictive, priority, flow control valve
- LKFC Pilot-to-open, spring-biased closed, unbalanced poppet logic element
- LKFCZ Pilot-to-open, spring-biased closed, unbalanced poppet logic element with position switch
- LOECZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with metering notches and position switch
- LOFA Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1
- LOFA8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 and integral T-8A control cavity
- LOFB Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2
- LOFB8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2 and integral T-8A control cavity
- LOFC Pilot-to-close, spring-biased closed, unbalanced poppet logic element
- LOFCZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with position switch
- LOFD Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2
- LOFD8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2 and integral T-8A control cavity
- LOFO Pilot-to-close, spring-biased open, unbalanced poppet logic element
- LOFOZ Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch
- LPFA Normally open, modulating element with pilot source from port 1
- LPFC Normally open, modulating element
- LPFCL Tuneable, normally open modulating element
- LRFA Normally closed, modulating element with pilot source from port 1
- LRFC Normally closed, modulating element
- LRFCL Tuneable, normally closed, modulating element
- PBFB Pilot-operated, pressure reducing valve
- PBFB8 Pilot-operated, pressure reducing main stage with integral T-8A control cavity
- PBFC Air-controlled, pilot-operated, pressure reducing valve
- PBFF Pilot-operated, pressure reducing valve with drilled piston orifice
- PBFF8 Pilot-operated, pressure reducing main stage with drilled piston orifice and integral T-8A control cavity
- PPFB Pilot-operated, pressure reducing/relieving valve
- PPFB8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity
- PPFC Air-controlled, pilot-operated, pressure reducing/relieving valve
- PPFF Pilot-operated, pressure reducing/relieving valve with drilled piston orifice
- PPFF8 Pilot-operated, pressure reducing/relieving main stage with drilled piston orifice and integral T-8A control cavity
- PRFB Direct-acting, pressure reducing/relieving valve
- PRFR Direct-acting, pressure reducing valve
- RSFC Pilot-operated, balanced piston sequence valve
- RSFC8 Pilot-operated, balanced piston sequence main stage with integral T-8A control cavity
- RSFE Air-controlled, pilot-operated, balanced piston sequence valve
- RSFS Pilot-operated, balanced poppet sequence valve
- RSFS8 Pilot-operated, balanced poppet sequence main stage with integral T-8A control cavity
- RVEA Ventable, pilot-operated, balanced piston relief valve
- RVEB Normally closed modulating element valve with relief function
- RVES Ventable, pilot-operated, balanced poppet relief valve
- RVET Anti-Shock, ventable, pilot-operated, balanced poppet relief valve
- SCEA Direct-acting sequence valve with reverse flow check
- SDFT Anti-Shock, pilot-operated, balanced poppet sequence valve with drain to port 3
- SQFB Kick-down, pilot-operated, balanced piston sequence valve
- SXEA Direct-acting sequence valve without reverse flow check
- XBAA Port 2 to 3 open, port 1 blocked cavity plug
- XBBA Port 1 to 3 open, port 2 blocked cavity plug
- XBCA All ports blocked cavity plug
- XBOA Port 1 to 2 open, port 3 blocked cavity plug
- XBOB All ports open cavity plug
Notes [ + ]
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]
Technical Information