Serie 2 - cavidad T-2A, Poliuretano cartucho juego de sellos
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
- Polyurethane seals have a higher tensile strength, are more abrasion/extrusion resistant, and are well suited for high cycle and high pressure applications.
Cartridge Installation Data [ + ]
Series | 2 |
Cartridge Thread | 1"-14 UNS1"-14 UNS |
Valve Hex Size | 1 1/8 in.28,6 mm |
Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
cavidad | T-2A |
Used With [ + ]
What models can this kit be used with?
- CBDA Proporción de pilotaje 3:1 , restrictiva contrabalance válvula
- CBDAX Ajuste fijo, proporción de pilotaje 3:1 , restrictiva contrabalance válvula
- CBDB Proporción de pilotaje 1.5:1 , semi-restrictiva contrabalance válvula
- CBDBX Ajuste fijo, proporción de pilotaje 1.5:1 , semi-restrictiva contrabalance válvula
- CBDC Proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
- CBDCX Ajuste fijo, proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
- CBDD Proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
- CBDDX Ajuste fijo, proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
- CBDG Proporción de pilotaje 4.5:1 , restrictiva contrabalance válvula
- CBDGX Ajuste fijo, proporción de pilotaje 4.5:1 , restrictiva contrabalance válvula
- CBDHX Ajuste fijo, proporción de pilotaje 10:1 , restrictiva contrabalance válvula
- CBDL Proporción de pilotaje 2.3:1 , semi-restrictiva contrabalance válvula
- CBEA Proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
- CBEAX Ajuste fijo, proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
- CBEB Proporción de pilotaje 1.5:1 , capacidad estándar contrabalance válvula
- CBEG Proporción de pilotaje 4.5:1 , capacidad estándar contrabalance válvula
- CBEH Proporción de pilotaje 10:1 , capacidad estándar contrabalance válvula
- CBEL Proporción de pilotaje 2.3:1 , capacidad estándar contrabalance válvula
- CBEY Proporción de pilotaje 2:1 , capacidad estándar contrabalance válvula
- CKEB Anti-retorno con pilotaje para abrir válvula con piloto estándar
- CKED Anti-retorno con pilotaje para abrir válvula con piloto sellado
- CKEV Anti-retorno venteado con pilotaje para abrir válvula - de referencia atmosférica
- CNED Caudal libre del lado a la nariz anti-retorno válvula con orificio de desvió y puerto 3 bloqueado
- CNEE Anti-retorno con pilotaje para abrir válvula con orificio de desvió
- CNFE Pilotaje para cerrar anti-retorno válvula con orificio de desvió
- COFA Pilotaje para cerrar anti-retorno válvula
- COFO Proporción de 120:1, pilotaje para cerrar anti-retorno válvula
- CXEE Caudal libre del lado a la nariz anti-retorno válvula con puerto 3 bloqueado
- CXFC Caudal libre de nariz al lado anti-retorno válvula con puerto 3 bloqueado
- DKFC Normalmente cerrado, disco balanceado, elemento lógico - pilotaje para abrir
- DKFD Normalmente cerrado, disco balanceado, elemento lógico - ventear-para-abrir
- DOFC Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar
- DOFD Normalmente abierto, disco balanceado, elemento lógico - ventear-para-cerrar
- DPCA 2-vías , pilot-operated, direccional válvula con drenaje interno al puerto 3 - normalmente abierto
- DPCB 2-vías , pilot-operated, direccional válvula con drenaje interno al puerto 3 - normalmente cerrado
- DPCC 3-vías, pilot-operated, direccional válvula con drenaje interno al puerto 3 (1 bloqueado, 2 a 3 abierto)
- DPCD 3-vías, pilot-operated, direccional válvula con drenaje interno al puerto 3 (1 a 2 abierto, 3 bloqueado)
- DRCC 3-vías, acción-directa , direccional válvula con drenaje interno al puerto 3 (1 bloqueado, 2 a 3 abierto)
- DVCA 2-vías , ventear-para-operar, direccional válvula con drenaje interno al puerto 3 y cavidad de control T-8A integral - normalmente abierto
- DVCB 2-vías , ventear-para-operar, direccional válvula con drenaje interno al puerto 3 y cavidad de control T-8A integral - normalmente cerrado
- DVCC 3-vías, ventear-para-operar, direccional válvula con drenaje interno al puerto 3 y cavidad de control T-8A integral (1 bloqueado, 2 a 3 abierto)
- DVCD 3-vías, ventear-para-operar, direccional válvula con drenaje interno al puerto 3 y cavidad de control T-8A integral (1 a 2 abierto, 3 bloqueado)
- FRDA Fixed-orifice, desvió /restrictivo, prioritario, control de caudal válvula
- LKFC Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico
- LKFCZ Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
- LOECZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con muescas de medición y indicador de posición
- LOFA Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1
- LOFA8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 y cavidad de control T-8A integral
- LOFB Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2
- LOFB8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2 y cavidad de control T-8A integral
- LOFC Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico
- LOFCZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
- LOFD Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2
- LOFD8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2 y cavidad de control T-8A integral
- LOFO Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico
- LOFOZ Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico con indicador de posición
- LPFA Normalmente abierto, elementos de modulación con fuente de pilotaje del puerto 1
- LPFC Normalmente abierto, elementos de modulación
- LPFCL Ajustable, normalmente abierto elementos de modulación
- LRFA Normalmente cerrado, elementos de modulación con fuente de pilotaje del puerto 1
- LRFC Normalmente cerrado, elementos de modulación
- LRFCL Ajustable, normalmente cerrado, elementos de modulación
- PBFB Pilot-operated, reductor de presión válvula
- PBFB8 Pilot-operated, reductor de presión módulo principal con cavidad de control T-8A integral
- PBFC Controlado por aire, pilot-operated, reductor de presión válvula
- PBFF Pilot-operated, reductor de presión válvula con orificio de pistón barrenado
- PBFF8 Pilot-operated, reductor de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
- PPFB Pilot-operated, reductor/alivio de presión válvula
- PPFB8 Pilot-operated, reductor/alivio de presión módulo principal con cavidad de control T-8A integral
- PPFC Controlado por aire, pilot-operated, reductor/alivio de presión válvula
- PPFF Pilot-operated, reductor/alivio de presión válvula con orificio de pistón barrenado
- PPFF8 Pilot-operated, reductor/alivio de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
- PRFB Acción-directa , reductor/alivio de presión válvula
- PRFR Acción-directa , reductor de presión válvula
- RSFC Pilot-operated, pistón balanceado secuencia válvula
- RSFC8 Pilot-operated, pistón balanceado secuencia módulo principal con cavidad de control T-8A integral
- RSFE Controlado por aire, pilot-operated, pistón balanceado secuencia válvula
- RSFS Pilot-operated, disco balanceado secuencia válvula
- RSFS8 Pilot-operated, disco balanceado secuencia módulo principal con cavidad de control T-8A integral
- RVEA De venteo, pilot-operated, pistón balanceado alivio válvula
- RVEB Normalmente cerrado elementos de modulación válvula con función de alivio
- RVES De venteo, pilot-operated, disco balanceado alivio válvula
- RVET Anti-Shock, de venteo, pilot-operated, disco balanceado alivio válvula
- SCEA Acción-directa secuencia válvula con anti-retorno de caudal inverso
- SDFT Anti-Shock, pilot-operated, disco balanceado secuencia válvula con drenaje al puerto 3
- SQFB Tirar-abajo, pilot-operated, pistón balanceado secuencia válvula
- SXEA Acción-directa secuencia válvula sin anti-retorno de caudal inverso
- XBAA Puerto 2 abierto al 3, puerto 1 bloqueado tapón de cavidad
- XBBA Puerto 1 abierto al 3, puerto 2 bloqueado tapón de cavidad
- XBCA Todos los puertos bloqueados tapón de cavidad
- XBOA Puerto 1 abierto al 2, puerto 3 bloqueado tapón de cavidad
- XBOB Todos los puertos abiertos tapón de cavidad
Notes [ + ]
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]
Technical Information