Solenoid-controlled priority By-pass diviseur de débit assemblage

Function

Function for XPFS: A - Normally Open 1 to 2
A - Normally Open 1 to 2
Function for XPFS: N - Normally Open 2 to 3
N - Normally Open 2 to 3
Port Designators [ + ]
Modifiers Ports
C, C/S Ports CF, EF, and P: 1/2" NPTF; Port T: 1/4" NPTF;
K, K/S Ports CF, EF, and P: SAE 10; Port T: SAE 4;
V, V/S Ports CF, EF, and P: 1/2" BSPP; Port T: 1/4" BSPP;
Caractéristiques techniques [ + ]

This assembly provides an efficient way to supply auxiliary hydraulic power to various systems. The assembly divides the inlet flow of Port P into a priority flow to port CF with excess flow to port EF, with ON/OFF control provided by the FLeX Series solenoid-operated directional valve. With the FLeX valve energized, the priority flow to CF is controlled via the adjustable needle valve. Maximum pressure to port CF can be independently adjusted with the relief. When not energized, all the flow will be diverted from port CF at 100 psi (7 bar) to port EF. The system will reach maximum pressure at maximum flow.

  • Sun Priority Flow Control assemblies utilize bypass/restrictive modulating elements, when combined with an adjustable needle valve, create a bypass/restrictive flow control. Inlet flow port P is directed to the priority or control flow at port 2 to the needle valve. The after-orifice (needle valve) signal is connected to port 1. Once the priority requirements are met, excess flow is bypassed to the EF.
  • The bypass/restrictive modulating element (LH*A) requires 100-psi (7-bar) differential pressure across the throttle valve before modulating to allow flow to EF port.
  • Note: Fully opening the needle valve may not generate the 100-psi (7-bar) differential required to shift the bypass/restrictive modulating element allowing flow to the EF port. The needle valve will need to be adjusted to ensure bypass flow to the EF port.
Caractéristiques [ + ]
Type de Corps Montage en ligneMontage en ligne
Capacité 30 gpm120 L/min.
Diamètre des Trous de Fixation 0,36 in.9,1 mm
Profondeur des Trous de Fixation TraversantTraversant
Nombre de Trous de Fixation 33
FAQs [ + ]

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Il y a exactement 15 gouttes Sun dans un centimètre cube.

Notes [ + ]
  • Important: La pression maximum du système doit être considérée avec une grande attention. La limite de pression maximum à laquelle le bloc peut être utilisé dépend de la matière du bloc, alors que le type et la dimension des orifices sont secondaires. Les blocs forés fabriqués en aluminium ne sont pas prévus pour des pressions supérieures à 210 bar (3000 psi), et ce quelles que soient les types et dimensions des orifices spécifiés.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Ressources Complémentaires [ + ]
infos pour les Bobines [ + ]

No coil selected.