Électro-proportionnel, à action directe, réducteur de pression 3 Voies Valve avec transition ouverte (740 Series)
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the relieving mode. Energizing the coil connects port 2 to port 1. Increasing the current to the coil will proportionally increase the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response. Optional full manual control is available.
This valve is designed to be used with 740 and 747 Series coils.
- La pression maximum recommandée à l’orifice 3 est 210 bar.
- La zone de transition entre la fonction réducteur de pression et limiteur de pression est légèrement ouverte. Il en résulte un très bon contrôle de la pression avec une fuite interne de 0,4 l/min. Le débit de pilotage relativement élevé est à prendre en compte lorsque le débit traversant la valve est bloqué.
- Toute pression à l’orifice 3 augmente directement la valeur de tarage de la valve dans un rapport de 1/1 et ne doit pas dépasser 210 bar.
- Pour optimiser les performances, il est recommandé d’utiliser un amplificateur ayant un bouclage de courant et un dither réglable entre 100 et 250 Hz.
- Note : Il n’y a pas de limitation du tarage avec la commande manuelle M. Plus la force exercée sur la commande de secours est grande, plus la pression qui en résulte est élevée.
- Un débit inverse venant de la pression réduite (orifice 1) vers l’entrée (orifice 2) peut entraîner la fermeture du tiroir principal. Si un passage libre du débit en sens inverse est nécessaire, il faut ajouter un clapet anti-retour séparé dans le circuit.
- Fully compatible with the XMD Expandable Mobile Drivers from Sun.
- La conception à action directe permet un fonctionnement très fiable dans les systèmes pollués, surtout dans les conditions où le débit est bloqué.
- Toutes les cartouches de réduction de pression (2 et 3 voies) à 3 orifices, sont physiquement et fonctionnellement interchangeables (c’est-à-dire le même sens de débit, la même cavité pour une taille donnée). Cependant, il est parfois conseillé d’utiliser une ligne de retour de grande capacité (orifice 3) pour les réducteurs de pression 3 voies.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-11A |
Taille | 1 |
Capacité | 5 gpm20 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 33.5 in³/min.550 cc/min. |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 7/8 in.22,2 mm |
Couple de serrage de la valve | 30 à 35 lbf ft41 - 47 Nm |
Poids du composant (avec la bobine) | 1,20 lb0,55 kg |
Seal kit - Cartridge | Buna: 990511007 |
Seal kit - Cartridge | Viton: 990611006 |
Seal and nut kit - Coil | Viton: 990740006 |
Hystérésis (avec dither) | 6%6% |
Hystérésis avec entrée de courant continu | <8%<8% |
Linéarité (avec dither) | <2%<2% |
Répétabilité (avec dither) | <2%<2% |
Fréquence de dither recommandée | 140 Hz140 Hz |
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.
2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.
When in doubt, use a reverse flow check.
Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.
Pour les pressions de tarage les tolérances sont indiquées dans notre page Performances et Caractéristiques Générales. Un lien vers cette page se trouve également dans l’onglet Ressources Complémentaires de la page produit correspondante.
Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.
No. A reducing/relieving valve throttles a supply of oil to maintain a set pressure in a secondary circuit. The valve is open until the secondary or downstream pressure rises to the setting of the valve at which time it starts to close to limit the pressure. If the secondary or downstream pressure is caused to go above the setting, the valve shifts into relieving mode and throttles the secondary circuit back to tank to prevent over-pressure. At no time can the valve connect the supply to tank.
Il y a exactement 15 gouttes Sun dans un centimètre cube.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Encore Une Solution Optimisée par Sun Hydraulics !
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Factory-tuned, optimized electro-hydraulics right out of the box
- Les Bases de l'Électro-Proportionnel
- CANpoint XMD Configuration Software
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Cartouches Sun avec joints EPDM
- Sun Étend ses Solutions Anticorrosion
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Réducteurs de Pression à 2 et 3 Voies (449.61 Ko)
- Amplificateurs Proportionnels et Produits Auxilliaires (2.06 Mo)
- Diviseurs de Débit et Diviseurs/Réunisseurs de Débit (1.27 Mo)
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- Recommandations pour les Fluides et les Températures
- Cartouches: Matières Utilisées dans les Produits SUN
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
- Electro-Hydraulic Terms and Definitions (2.94 Mo)
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
No coil selected.