Électro-proportionnel 3 Voies contrôle de débit Valve, régulation en entrée de récepteur (740 Series)
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1-to-2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2-to-3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2-to-3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDFs in conjunction with a cushion lock circuit create a meter-in/meter-out 3-position 4-way.
- Note : Le débit est limité à 5 l/min de 2 vers 3.
- La transition entre les 2 positions est fermée.
- L'utilisation de 2 valves 3 voies pour créer une valve 4 voies permet une sélection parmi les gammes de débit existantes au lieu de réaliser un tiroir spécial.
- Cette valve peut être compensée en pression par un élément de régulation externe. Utilisez un LR_C-XHN pour un circuit 3 voies ou un LP_C-XHN pour un circuit 2 voies.
- La valve a une certaine capacité d’auto-compensation et peut être utilisée comme valve de contrôle de débit. Pour augmenter la précision du contrôle de débit, un élément de régulation externe permet de maintenir un débit constant pour une large plage de débits et de pressions. Consulter les courbes caractéristiques pour plus d'informations.
- For optimum performance, an amplifier with current feedback and adjustable dither (100 - 250 Hz) should be used.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-11A |
Taille | 1 |
Capacité | 9 gpm34 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
Force Nécessaire pour la Commande Manuelle | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
Course de la Commande Manuelle | 0,1 in.2,5 mm |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 7/8 in.22,2 mm |
Couple de serrage de la valve | 30 à 35 lbf ft41 - 47 Nm |
Hystérésis (avec dither) | <4%<4% |
Hystérésis avec entrée de courant continu | <8%<8% |
Linéarité (avec dither) | <2%<2% |
Répétabilité (avec dither) | <2%<2% |
Fréquence de dither recommandée | 140 Hz140 Hz |
All flow is blocked, hence the term priority. The priority flow has to be satisfied.
The valve acts as a 2 port restrictive flow control.
The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.
Il y a exactement 15 gouttes Sun dans un centimètre cube.
In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.
We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.
I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- Encore Une Solution Optimisée par Sun Hydraulics !
- SUNs kleinste 2- und 3-Wege Druckminderventile bieten beste Eigenschaften auch bei kleinen Volumenströmen.
- Conseils Techniques pour les Clapets Anti-Retour, les Valves de Contrôle du Débit et les Régulateurs 3 Voies à Débit Prioritaire
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Étend ses Solutions Anticorrosion
- Valve d’Etranglement Électro-proportionnelle Haute Capacité
- Factory-tuned, optimized electro-hydraulics right out of the box
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Les Valves Proportionnelles Sun Permettent la Régulation en Entrée et en Sortie de Récepteur dans les Circuits de Contrôle des Mouvements
- CANpoint XMD Configuration Software
- CavitySaver multi-function valves deliver single-cartridge solutions
- Cartouches Sun avec joints EPDM
- Les Bases de l'Électro-Proportionnel
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Amplificateurs Proportionnels et Produits Auxilliaires (2.06 Mo)
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Clapets Anti-Retour, Valves de Contrôle du Débit et Régulateurs T (536.99 Ko)
- Diviseurs de Débit et Diviseurs/Réunisseurs de Débit (1.27 Mo)
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- Cartouches: Matières Utilisées dans les Produits SUN
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Electro-Hydraulic Terms and Definitions (2.94 Mo)
- Performances et Caractéristiques Générales