FLeX Series 3 Voies, à action directe, électro distributeur blocking Clapet Valve
This FLeX Series solenoid-operated 3-way, 2-position cartridge is a direct-acting, poppet-style directional valve.
Due to the poppet style construction, this valve has extremely low leakage.
- Cette valve est à action directe et ne nécessite pas de minimum de pression hydraulique pour fonctionner.
- Cette valve convient aux applications de maintien de charge.
- Port 3 is the preferred inlet for this valve. Port 1 is limited to half capacity.
- Designed and tested to 10-million operational cycles at full-rated pressure.
- Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Designed using CFD simulation for optimized geometries.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This valve exhibits extremely low leakage - 0.004 in3 (0,07 cc)/min (1 drop/min).
- Manual push-version override options are available in the "A" poppet configurations (DWBF-*A*). The force on the "M" manual override must not exceed 25 lbf (110 N).
- Pour les modèles équipés du dispositif de contrôle D ou L, le mécanisme d'indexage présent dans la commande manuelle est destiné à des actionnements temporaires. Les commandes manuelles de secours D, L et T ont une espérance de vie mécanique de 7000 cycles environ.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- Le noyau du solénoïde est à bain d’huile, ce qui signifie que le fluide du système, qui entoure le noyau, est soumis à la chaleur générée par la bobine. Il faut en tenir compte dans les cas où la bobine est excitée pendant une durée prolongée. Certains fluides, notamment les mélanges eau/glycol, se détériorent à ces températures et avec le temps, des vernis se forment et peuvent affecter le fonctionnement de la cartouche.
- Une large gamme d’options de connexions et de tensions d’alimentation des bobines est disponible, avec ou sans diode "Roue Libre" anti-self. Voir la section CONFIGURATION.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-150A |
Taille | 0 |
Capacité | 6 gpm23 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 0.004 in³/min.@5000 psi0,07 cc/min.@350 bar |
Temps de Réponse - Typique | 50 ms50 ms |
Fréquence de commutation | 10,000 max. cycles/hr10,000 max. cycles/hr |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 3/4 in.19,1 mm |
Couple de serrage de la valve | 25 à 30 lbf ft35 - 40 Nm |
Poids du composant | 1,25 lb0,60 kg |
Brevet Américain # | 10,302,20110,302,201 |
Seal kit - Cartridge | Buna: 990150007 |
Seal kit - Cartridge | Viton: 990150006 |
Seal and nut kit - Coil | Viton: 990740006 |
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Il y a exactement 15 gouttes Sun dans un centimètre cube.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
Yes. All FLeX phase 1 valves are available in the SmartConnect schematic tool, and are also available for submittal to QuickDesign.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- Sun Hydraulics bases solenoid valve performance data on testing at maximum ambient temperature (50° C) and 15% undervoltage at stabilized current (580 mA). This ensures that our data represents valve performance under worst-case conditions.
- Cartouches Sun avec joints EPDM
- Encore Une Solution Optimisée par Sun Hydraulics !
- Distributeurs à Commande Manuelle
- New FLeX Series Solenoid-Operated Directional Valves
- SUNs kleinste 2- und 3-Wege Druckminderventile bieten beste Eigenschaften auch bei kleinen Volumenströmen.
- Conseils Techniques pour les Distributeurs à Commande Électrique
- FLeX Series 3-way directional blocking poppet valves
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Distributeurs et Étrangleurs Proportionnels, à Commande Hydraulique
- Conseils Techniques pour les Distributeurs Pilotés
- Sun Étend ses Solutions Anticorrosion
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Nouvelles Électrovalves de Pilotage Sun
- Pourquoi attendre ? Obtenez Sun’s FLeX valves & nos nouveaux XMD modules quand vous les voulez.
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Électrovalves (1.18 Mo)
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Distributeurs à Pilotage Interne (629.36 Ko)
- Units of Measure, Settings, and Conversions
- Cartouches: Matières Utilisées dans les Produits SUN
- Performances et Caractéristiques Générales
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- 747 Series Hazardous Location Coils - ATEX Certificate (976.94 Ko)
- 747 Series Hazardous Location Coils - CSA Certificate of Complian (106.22 Ko)
- 747 Series Hazardous Location Coils - IECEx Certificate of Confor (285.26 Ko)
No coil selected.