2 Voies, à action directe, à clapet équilibré électro distributeur Valve - common cavity

Capacité: 6 gpm23 L/min. | Cavité: SC-08-02
DTTA : 2 Voies, à action directe, à clapet équilibré électro distributeur Valve - common cavity
Caractéristiques techniques [ + ]

This solenoid-operated, 2-way, 2-position cartridge is a direct-acting, directional balanced poppet valve.

  • Cette valve est à action directe et ne nécessite pas de minimum de pression hydraulique pour fonctionner.
  • La fatigue du tube recevant le solénoïde est calculée pour une pression de service de 250 bar (3600 psi)
  • The cartridge installation torque of 22 lbf ft (30 Nm) should be respected for best performance.
  • All ports are rated to a maximum operating pressure of 3600 psi (250 bar).
  • The valve is available with a manual push-type, with detent, override option (L control). This option is also fatigue rated for 5000 psi (350 bar).
  • Coil connector options offer ratings up to IP67. See individual coil product pages for details.
  • The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
  • Coils can be mounted on the tube in either direction.
Caractéristiques [ + ]
Remarque: Les caractéristiques peuvent changer selon la configuration. Voir la section CONFIGURATION.
Cavité SC-08-02
Taille 0C
Capacité 6 gpm23 L/min.
Pression maximale de fonctionnement 3600 psi250 bar
Fuite Maximale à 24 cSt (100 SUS) 15 drops/min.@3600 psi15 drops/min.@3600 psi
Temps de Réponse - Typique 50 ms50 ms
Fréquence de commutation 15,000 max. cycles/hr15,000 max. cycles/hr
Diamètre du Doigt de Gant .51 in..51 in.
Dimensions du six pans de la valve 7/8 in.22,2 mm
Couple de Serrage de l'Ecrou de la Bobine 3.5 - 3.9 lbf ft4,8 - 5,3 Nm
Couple de serrage de la valve 21 - 23 lbf ft28 - 31 Nm
Poids du composant 0,35 lb0,15 kg
Seal kit - Cartridge Buna: 99C083007
Seal kit - Cartridge Viton: 99C083006
Performance Curves [ + ]
FAQs [ + ]

Il y a exactement 15 gouttes Sun dans un centimètre cube.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.

Ressources Complémentaires [ + ]
infos pour les Bobines [ + ]

No coil selected.