2 Voies, 2-stage, électro distributeur Clapet Valve - common cavity
This solenoid-operated, 2-way, 2-position cartridge is a pilot-operated, directional poppet valve. This valve offers 2-position, 2-way directional control with a lower pressure drop than its direct-acting counterpart. The valve is available in the normally open and normally closed condition.
- L’ensemble du doigt de gant du solénoïde est dimensionné pour fonctionner à 350 bar, hors limite de fatigue.
- All ports are rated to a maximum operating pressure of 5000 psi (350 bar).
- This valve is not suitable for load-holding. Up to 9 in3/min (147 mL/min) of leakage is allowed when below a pressure differential of 1000 psi (70 bar) between its ports.
- The cartridge installation torque of 37 lbf-ft (50 Nm) is required for best performance.
- The valve is available with a manual push-type, with detent, override option (L control) on the normally open configuration. This option is also fatigue rated for 5000 psi (350 bar).
- The valve is available with a manual unscrew-type override option (L control) on the normally closed configuration. This option is also fatigue rated for 5000 psi (350 bar).
- The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
- Coil connector options offer ratings up to IP67. See individual coil product pages for details.
- Coils can be mounted on the tube in either direction.
Cavité | SC-12-02 |
Taille | 2C |
Capacité | 40 gpm160 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Typical Valve Leakage at 110 SUS (24cSt) - Normally Open | 7 mL/min.@5000 psi7 mL/min.@5000 psi |
Typical Valve Leakage at 110 SUS (24cSt) - Normally Closed | 3 mL/min.@5000 psi3 mL/min.@5000 psi |
Temps de Réponse - Typique | 300 ms300 ms |
Diamètre du Doigt de Gant | 0,75 in.19 mm |
Dimensions du six pans de la valve | 1,00 in.25,4 mm |
Couple de Serrage de l'Ecrou de la Bobine | 3.5 - 3.9 lbf ft4,8 - 5,3 Nm |
Couple de serrage de la valve | 36 - 38 lbf ft49 - 52 Nm |
Poids du composant | 0,65 lb0,30 kg |
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Électrovalves 2 Voies Haute Capacité
- Cartouches Sun avec joints EPDM
- Encore Une Solution Optimisée par Sun Hydraulics !
- Conseils Techniques pour les Distributeurs à Commande Électrique
- Sun Étend ses Solutions Anticorrosion
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Conseils Techniques pour les Distributeurs Pilotés
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- New FLeX Series Solenoid-Operated Directional Valves
- Électrovalves Haute Capacité
- Distributeurs à Commande Manuelle
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Nouvelles Électrovalves de Pilotage Sun
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Électrovalves (1.18 Mo)
- Distributeurs à Pilotage Interne (629.36 Ko)
- Distributeurs à Pilotage Externe (418.4 Ko)
- Cartouches: Matières Utilisées dans les Produits SUN
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
No coil selected.