2 Voies, 2-stage, électro distributeur Clapet Valve - flow 2-1 (740 Series)
This solenoid controlled, 2-way, 2-position cartridge is a pilot-operated, poppet style directional valve with reverse free flow check. It is available in either a normally open or normally closed configuration. Due to its poppet style construction, it has extremely low leakage.
This valve is designed to be used with 740 and 747 Series coils.
- L’ensemble du doigt de gant du solénoïde est dimensionné pour fonctionner à 350 bar, hors limite de fatigue.
- Les cartouches configurées avec des joints EPDM s’utilisent dans les systèmes avec des fluides ester phosphate. L’exposition de ces joints à des fluides à base de pétrole, de graisse ou de lubrifiant détériorera les joints.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This cartridge has an option for manual override. See the CONFIGURATION section.
- Ces valves ont un débit de fuite extrêmement faible : moins de 10 gouttes/min (0,7 cm3/min) à 350 bar (5000 psi)
- Pour les modèles équipés du dispositif de contrôle D ou L, le mécanisme d'indexage présent dans la commande manuelle est destiné à des actionnements temporaires. Les commandes manuelles de secours D, L et T ont une espérance de vie mécanique de 7000 cycles environ.
- Le noyau du solénoïde est à bain d’huile, ce qui signifie que le fluide du système, qui entoure le noyau, est soumis à la chaleur générée par la bobine. Il faut en tenir compte dans les cas où la bobine est excitée pendant une durée prolongée. Certains fluides, notamment les mélanges eau/glycol, se détériorent à ces températures et avec le temps, des vernis se forment et peuvent affecter le fonctionnement de la cartouche.
- Une large gamme d’options de connexions et de tensions d’alimentation des bobines est disponible, avec ou sans diode "Roue Libre" anti-self. Voir la section CONFIGURATION.
- La conception unique de ce solénoïde assure une grande efficacité. La force de commande du tiroir par Watt utilisé est élevée et assure une bonne fiabilité de commutation de la valve.
- Coils can be mounted on the tube in either direction.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-16A |
Taille | 3 |
Capacité | 60 gpm240 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Pression d'ouverture du clapet de by-pass | 50 psi3,5 bar |
Temps de Réponse - Typique | 30 ms30 ms |
Fréquence de commutation | 15,000 max. cycles/hr15,000 max. cycles/hr |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 1"1/4 in.31,8 mm |
Couple de serrage de la valve | 150 à 160 lbf ft203 - 217 Nm |
Poids du composant | 1,40 lb0,65 kg |
Seal kit - Cartridge | Buna: 990016007 |
Seal kit - Cartridge | EPDM: 990016014 |
Seal kit - Cartridge | Viton: 990016006 |
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Il y a exactement 15 gouttes Sun dans un centimètre cube.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- New FLeX Series Solenoid-Operated Directional Valves
- Électrovalves Haute Capacité
- Distributeurs à Commande Manuelle
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Électrovalves 2 Voies Haute Capacité
- Cartouches Sun avec joints EPDM
- Encore Une Solution Optimisée par Sun Hydraulics !
- Conseils Techniques pour les Distributeurs à Commande Électrique
- Sun Étend ses Solutions Anticorrosion
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Conseils Techniques pour les Distributeurs Pilotés
- Nouvelles Électrovalves de Pilotage Sun
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Électrovalves (1.18 Mo)
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Distributeurs à Pilotage Interne (629.36 Ko)
- Distributeurs à Pilotage Externe (418.4 Ko)
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
- Cartouches: Matières Utilisées dans les Produits SUN
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
No coil selected.