2 Voies, 2-stage, électro distributeur Clapet Valve - flow 1-2 (740 Series)
This solenoid controlled, 2-way, 2-position cartridge is a pilot-operated, poppet style directional valve with reverse free flow check. It is available in either a normally open or normally closed configuration. Due to its poppet style construction, it has extremely low leakage.
This valve is designed to be used with 740 and 747 Series coils.
- L’ensemble du doigt de gant du solénoïde est dimensionné pour fonctionner à 350 bar, hors limite de fatigue.
- Les cartouches configurées avec des joints EPDM s’utilisent dans les systèmes avec des fluides ester phosphate. L’exposition de ces joints à des fluides à base de pétrole, de graisse ou de lubrifiant détériorera les joints.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This cartridge has an option for manual override. See the CONFIGURATION section.
- Ces valves ont un débit de fuite extrêmement faible : moins de 10 gouttes/min (0,7 cm3/min) à 350 bar (5000 psi)
- Pour les modèles équipés du dispositif de contrôle D ou L, le mécanisme d'indexage présent dans la commande manuelle est destiné à des actionnements temporaires. Les commandes manuelles de secours D, L et T ont une espérance de vie mécanique de 7000 cycles environ.
- Le noyau du solénoïde est à bain d’huile, ce qui signifie que le fluide du système, qui entoure le noyau, est soumis à la chaleur générée par la bobine. Il faut en tenir compte dans les cas où la bobine est excitée pendant une durée prolongée. Certains fluides, notamment les mélanges eau/glycol, se détériorent à ces températures et avec le temps, des vernis se forment et peuvent affecter le fonctionnement de la cartouche.
- Une large gamme d’options de connexions et de tensions d’alimentation des bobines est disponible, avec ou sans diode "Roue Libre" anti-self. Voir la section CONFIGURATION.
- La conception unique de ce solénoïde assure une grande efficacité. La force de commande du tiroir par Watt utilisé est élevée et assure une bonne fiabilité de commutation de la valve.
- Coils can be mounted on the tube in either direction.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-16A |
Taille | 3 |
Capacité | 60 gpm240 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Pression d'ouverture du clapet de by-pass | 50 psi3,5 bar |
Temps de Réponse - Typique | 30 ms30 ms |
Fréquence de commutation | 15,000 max. cycles/hr15,000 max. cycles/hr |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 1"1/4 in.31,8 mm |
Couple de serrage de la valve | 150 à 160 lbf ft203 - 217 Nm |
Poids du composant | 1,40 lb0,65 kg |
Seal kit - Cartridge | Buna: 990016007 |
Seal kit - Cartridge | EPDM: 990016014 |
Seal kit - Cartridge | Viton: 990016006 |
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- Encore Une Solution Optimisée par Sun Hydraulics !
- Conseils Techniques pour les Distributeurs à Commande Électrique
- Sun Étend ses Solutions Anticorrosion
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Conseils Techniques pour les Distributeurs Pilotés
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- New FLeX Series Solenoid-Operated Directional Valves
- Électrovalves Haute Capacité
- Distributeurs à Commande Manuelle
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Électrovalves 2 Voies Haute Capacité
- Cartouches Sun avec joints EPDM
- Nouvelles Électrovalves de Pilotage Sun
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Électrovalves (1.18 Mo)
- Distributeurs à Pilotage Interne (629.36 Ko)
- Distributeurs à Pilotage Externe (418.4 Ko)
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
- Cartouches: Matières Utilisées dans les Produits SUN
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
No coil selected.