2-vías , direccional, operada por solenoide carrete válvula - capacidad de pilotaje

Capacidad: .25 gpm1 L/min. | Cavidad: T-8A
DAAA : 2-vías , direccional, operada  por solenoide  carrete válvula  - capacidad de pilotaje
Technical Features [ + ]

This solenoid-operated 2-way, 2-position cartridge is a direct-acting, balanced spool pilot valve used to pilot other full-flow valves. The valve is available in either a normally open or normally closed configuration.

This cartridge can be installed directly into a cavity in the end of many of Sun's pilot operated and ventable valves to provide integrated pilot control.

  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • This valve is direct actuated and requires no minimum hydraulic pressure for operation.
  • Cartridge can be installed directly into a cavity in some Sun pilot operated and ventable cartridges to provide electrically operated pilot control functions. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function.
  • Highly efficient tube design requires only 12 Watts to shift the valve.
  • Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
  • A manual push-type override is a standard feature.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Coils are interchangeable with other Sun Series P pilot solenoid products and can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-8A
Series P
Capacity .25 gpm1 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 10 drops/min.@5000 psi0,7 cc/min.@350 bar
Manual Override Force Requirement 10 lbs/1000 psi @ Port 166 N/100 bar @ Port 1
Response Time - Typical 30 ms30 ms
Switching Frequency 15,000 max. cycles/hr15,000 max. cycles/hr
Solenoid Tube Diameter .56 in.14,2 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 20 - 25 lbf ft27 - 33 Nm
Model Weight .30 lb0,15 kg
Seal and nut kit - Coil Viton: 990760006
Seal kit - Cartridge Buna: 990008007
Seal kit - Cartridge EPDM: 990308114
Seal kit - Cartridge Polyurethane: 990008002
Seal kit - Cartridge Viton: 990008006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Additional Resources [ + ]
Coil Information [ + ]

No coil selected.