2-vías , ventear-para-operar, direccional válvula con drenaje al puerto 4 y cavidad de control T-8A integral - normalmente cerrado
Capacidad: 7 gpm28 L/min. |
Cavidad: T-21A
Technical Features [ + ]
This valve is a normally closed, 2-way directional cartridge that incorporates an integral pilot control cavity. It may be used by itself or to actuate larger pilot-operated directional cartridges or logic elements. The valve shifts when there is flow through the pilot control cartridge installed in the T-8A cavity.
- Port 3 can be used as a work port.
- The flow path between port 2 and port 3 is bidirectional.
- NOTE: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- There must be a pressure source at port 1, relative to port 4, to shift the valve.
- The -8 control option allows the pilot control valve to be incorporated directly into the end of the directional cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include solenoid operation, air pilot operation, and hydraulic pilot operation. See Pilot Control Cartridges.
- Leakage listed in technical data is for each path.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad | T-21A |
Series | 1 |
Capacity | 7 gpm28 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
Pilot Control Cavity | T-8AT-8A |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Model Weight | .50 lb0,25 kg |
Seal kit - Cartridge | Buna: 990021007 |
Seal kit - Cartridge | Polyurethane: 990021002 |
Seal kit - Cartridge | Viton: 990021006 |
Performance Curves [ + ]
FAQs [ + ]
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
- Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.
Additional Resources [ + ]
Realces
- Sun Cartridges with EPDM Seals
- Nuevas válvulas direccionales accionadas por solenoide de la serie FLeX
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign con SmartConnect Ofrece una Herramienta para Construir Esquemáticos
- Manually Operated Directional Valves
- Pilot Controlled Directional Cartridges Technical Tips
- Válvulas y bobinas a solenoides de la serie Sun FLeX
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
Technical Tips
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Pilot Controlled Directional Cartridges (629.97 KB)
Technical Information