3-vías, pilot-operated, direccional válvula con drenaje al puerto 4 (1 a 2 abierto, 3 bloqueado)
Pilot-operated, 3-way directional cartridges (1 to 2 open, 3 blocked) are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
- Port 4 can be blocked to prevent the valve from shifting.
- Port 3 can be used as a work port.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- Pressure at port 4 is directly additive to the setting of the valve.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
cavidad | T-22A |
Series | 2 |
Capacity | 15 gpm60 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Factory Pressure Settings Established at | 4 gpm15 L/min. |
Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
Maximum Valve Leakage at 110 SUS (24 cSt) | 1 in³/min.@1000 psi15 cc/min.@70 bar |
Adjustment - No. of CW Turns from Min. to Max. setting | 55 |
Valve Hex Size | 1 1/8 in.28,6 mm |
Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
Locknut Hex Size | 9/16 in.15 mm |
Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
Model Weight | .60 lb0,30 kg |
Seal kit - Cartridge | Buna: 990022007 |
Seal kit - Cartridge | Polyurethane: 990022002 |
Seal kit - Cartridge | Viton: 990022006 |
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
DP**s and DR**s are from the reducer/reliever family and are very capable of modulating. They are not bistable.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
- Pilot Controlled Directional Cartridges Technical Tips
- Nuevas válvulas direccionales de bloqueo por asiento de 3 vías de la serie FLeX ™
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Válvulas y bobinas a solenoides de la serie Sun FLeX
- Pilot-to-Shift Directional Valves and Proportional Throttles
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Nuevas válvulas direccionales accionadas por solenoide de la serie FLeX
- Manually Operated Directional Valves
- QuickDesign con SmartConnect Ofrece una Herramienta para Construir Esquemáticos
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Pilot Controlled Directional Cartridges (629.97 KB)