Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar
This is a normally open, balanced poppet, switching element. Pilot pressure at port 3 shifts the valve to the closed position.
- Unique balanced construction provides predictable switching with 5000 psi (350 bar) at both ports 1 and 2, with the external drain open and a minimum pilot pressure of 300 psi (20 bar).
- Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
- Any backpressure at the drain port is directly additive to the required pilot pressure for reliable operation.
- Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
- Valve will open when the pilot pressure falls below 145 psi (10 bar).
- These valves are hydraulically balanced between port 1 and port 2.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- All ports will accept 5000 psi (350 bar).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
cavidad | T-22A |
Series | 2 |
Capacity | 30 gpm120 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Minimum Pilot Pressure Required to Shift Valve | 300 psi20 bar |
Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Pilot Volume Displacement | .02 in³0,33 cc |
Valve Hex Size | 1 1/8 in.28,6 mm |
Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
Seal kit - Cartridge | Buna: 990022007 |
Seal kit - Cartridge | EPDM: 990022014 |
Seal kit - Cartridge | Polyurethane: 990022002 |
Seal kit - Cartridge | Viton: 990022006 |
Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- More Options for Logic Elements with Position-Indicating Switch
- Nuevas válvulas direccionales accionadas por solenoide de la serie FLeX
- Sun Cartridges with EPDM Seals
- QuickDesign con SmartConnect Ofrece una Herramienta para Construir Esquemáticos
- Take the Guesswork Out of Logic Circuits
- Reduce el impacto de descompresión y sus costos de operación
- Pilot Controlled Directional Cartridges Technical Tips
- Válvulas CavitySaver de multifunción ofrecen varias soluciones en una
- Sun Expands Corrosion-Resistant Solutions
- Válvulas y bobinas a solenoides de la serie Sun FLeX
- Logic Element Cartridges Technical Tips
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Logic Element Cartridges (886.29 KB)