Normalmente abierto, disco balanceado, elemento lógico con cavidad de control T-8A integral - ventear-para-cerrar
This is a normally open, balanced poppet, switching element with an integral T-8A control cavity. With a 2-way valve in the closed position installed in the T-8A control cavity, the poppet remains open. Opening the 2-way valve shifts the poppet to the closed position, provided there is sufficient pressure at port 3.
- Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2. Switching will only occur when both a minimum pilot pressure of 400 psi (30 bar) is present and pilot control valve is open.
- Valve will open when the pilot pressure falls below 145 psi (10 bar).
- These valves are hydraulically balanced between port 1 and port 2.
- Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
- Any backpressure at the drain port is directly additive to the required pilot pressure for reliable operation.
- Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
- NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
- The -8 control option allows the pilot control valve to be incorporated directly into the end of the logic cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
- All ports will accept 5000 psi (350 bar).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
cavidad | T-21A |
Series | 1 |
Capacity | 15 gpm60 L/min. |
Maximum Operating Pressure | 5000 psi350 bar |
Minimum Pilot Pressure Required to Shift Valve | 400 psi28 bar |
Control Pilot Flow | See Performance DataSee Performance Data |
Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Pilot Control Cavity | T-8AT-8A |
Pilot Control Valve Installation Torque | 20 - 25 lbf ft27 - 33 Nm |
Pilot Control Valve Hex Size | 7/8 in.22,2 mm |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Model Weight | .35 lb0,15 kg |
Seal kit - Cartridge | Buna: 990021007 |
Seal kit - Cartridge | Polyurethane: 990021002 |
Seal kit - Cartridge | Viton: 990021006 |
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.
- Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.
- Sun Expands Corrosion-Resistant Solutions
- Válvulas y bobinas a solenoides de la serie Sun FLeX
- Logic Element Cartridges Technical Tips
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- More Options for Logic Elements with Position-Indicating Switch
- Nuevas válvulas direccionales accionadas por solenoide de la serie FLeX
- Sun Cartridges with EPDM Seals
- QuickDesign con SmartConnect Ofrece una Herramienta para Construir Esquemáticos
- Take the Guesswork Out of Logic Circuits
- Reduce el impacto de descompresión y sus costos de operación
- Pilot Controlled Directional Cartridges Technical Tips
- Válvulas CavitySaver de multifunción ofrecen varias soluciones en una
- Manufacturing Sun Cartridge Cavities (522.27 KB)
- Logic Element Cartridges (886.29 KB)