Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar

Capacidad: 15 gpm60 L/min. | Cavidad: T-11A
DODC : Normalmente abierto, disco balanceado, elemento lógico  - pilotaje para cerrar
Technical Features [ + ]

This is a normally open, balanced poppet, switching element. Pilot pressure at port 3 shifts the valve to the closed position.

  • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at both ports 1 and 2, with the external drain open and a minimum pilot pressure of 400 psi (30 bar).
  • Valve will open when the pilot pressure falls below 145 psi (10 bar).
  • These valves are hydraulically balanced between port 1 and port 2.
  • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
  • These 3-port balanced logic valves use the same cavity as unbalanced logic valves of the same frame size and can be considered functional replacements.
  • Available in external atmospheric vent (X control) or static external drain (E control) configurations.
  • Three-port vented logic elements with the X control are atmospherically referenced and considered problem solvers for existing circuits using non-vented valves. Over time, these valves will eventually leak externally and/or allow moisture into the spring chamber. Four-port valves are recommended for new applications. Alternately, the external vent port can be connected to drain if the static drain port option (control option E) is selected. Removing the vent plug will convert an X control to an E control.
  • Port 1 and port 2 are fully sealed from port 3.
  • All ports will accept 5000 psi (350 bar).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-11A
Series 1
Capacity 15 gpm60 L/min.
Maximum Operating Pressure 5000 psi350 bar
Minimum Pilot Pressure Required to Shift Valve 400 psi28 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 10 drops/min.@5000 psi0,7 cc/min.@350 bar
Pilot Volume Displacement .01 in³0,16 cc
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .35 lb0,15 kg
Seal kit - Cartridge Buna: 990311007
Seal kit - Cartridge Viton: 990311006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Additional Resources [ + ]