Caudal libre de nariz al lado anti-retorno válvula - common cavity

Capacidad: 10 gpm40 L/min. | Cavidad: SC-08-02
CXTA : Caudal libre de nariz al lado  anti-retorno válvula  - common cavity
Technical Features [ + ]

This nose-to-side check valve allows free flow from the inlet (Port 1) to the outlet (Port 2) and blocks flow in the opposite direction.

  • Will accept 5000 psi (350 bar) at ports 1 and 2.
  • This Check valve offers an extremely low leakage rate with a maximum leakage of less than 5 drops per minute (0,33 cc/min).
  • The cartridge installation torque of 30 lbf-ft (40,7 Nm) is required for best performance.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad SC-08-02
Series 0C
Capacity 10 gpm40 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 drops/min.0,3 cc/min.
Valve Hex Size 24 mm24 mm
Valve Installation Torque 19 - 22 lbf ft26 - 30 Nm
Model Weight .20 lb0,10 kg
Performance Curves [ + ]
FAQs [ + ]

Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Additional Resources [ + ]