Serie 3 - cavidad T-17A, Poliuretano, cartucho juego de sellos
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
- Polyurethane seals have a higher tensile strength, are more abrasion/extrusion resistant, and are well suited for high cycle and high pressure applications.
Technical Data [ + ]
Series | 3 |
Cartridge Thread | 1"-14 UNS1"-14 UNS |
Valve Hex Size | 1 1/4 in.31,8 mm |
Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
cavidad | T-17A |
Used With [ + ]
What models can this kit be used with?
- CBFA Proporción de pilotaje 3:1 , restrictiva contrabalance válvula
- CBFB Proporción de pilotaje 1.5:1 , semi-restrictiva contrabalance válvula
- CBFC Proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
- CBFD Proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
- CBFG Proporción de pilotaje 4.5:1 , restrictiva contrabalance válvula
- CBFL Proporción de pilotaje 2.3:1 , semi-restrictiva contrabalance válvula
- CBGA Proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
- CBGB Proporción de pilotaje 1.5:1 , capacidad estándar contrabalance válvula
- CBGG Proporción de pilotaje 4.5:1 , capacidad estándar contrabalance válvula
- CBGH Proporción de pilotaje 10:1 , capacidad estándar contrabalance válvula
- CBGL Proporción de pilotaje 2.3:1 , capacidad estándar contrabalance válvula
- CBGY Proporción de pilotaje 2:1 , capacidad estándar contrabalance válvula
- CKGB Anti-retorno con pilotaje para abrir válvula con piloto estándar
- CKGD Anti-retorno con pilotaje para abrir válvula con piloto sellado
- CKGV Anti-retorno venteado con pilotaje para abrir válvula - de referencia atmosférica
- CNGD Caudal libre del lado a la nariz anti-retorno válvula con orificio de desvió y puerto 3 bloqueado
- CNGE Anti-retorno con pilotaje para abrir válvula con orificio de desvió
- CNHE Pilotaje para cerrar anti-retorno válvula con orificio de desvió
- COHA Pilotaje para cerrar anti-retorno válvula
- CXGE Caudal libre del lado a la nariz anti-retorno válvula con puerto 3 bloqueado
- CXHC Caudal libre de nariz al lado anti-retorno válvula con puerto 3 bloqueado
- DKHC Normalmente cerrado, disco balanceado, elemento lógico - pilotaje para abrir
- DKHD Normalmente cerrado, disco balanceado, elemento lógico - ventear-para-abrir
- DOHC Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar
- DOHD Normalmente abierto, disco balanceado, elemento lógico - ventear-para-cerrar
- FREA Fixed-orifice, desvió /restrictivo, prioritario, control de caudal válvula
- LKHC Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico
- LKHCZ Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
- LOGCZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con muescas de medición y indicador de posición
- LOHA Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1
- LOHA8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 y cavidad de control T-8A integral
- LOHB Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2
- LOHB8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2 y cavidad de control T-8A integral
- LOHC Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico
- LOHCZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
- LOHD Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2
- LOHD8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2 y cavidad de control T-8A integral
- LOHO Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico
- LOHOZ Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico con indicador de posición
- LPHA Normalmente abierto, elementos de modulación con fuente de pilotaje del puerto 1
- LPHC Normalmente abierto, elementos de modulación
- LRHA Normalmente cerrado, elementos de modulación con fuente de pilotaje del puerto 1
- LRHC Normalmente cerrado, elementos de modulación
- PBHB Pilot-operated, reductor de presión válvula
- PBHB8 Pilot-operated, reductor de presión módulo principal con cavidad de control T-8A integral
- PBHC Controlado por aire, pilot-operated, reductor de presión válvula
- PBHF Pilot-operated, reductor de presión válvula con orificio de pistón barrenado
- PBHF8 Pilot-operated, reductor de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
- PPHB Pilot-operated, reductor/alivio de presión válvula
- PPHB8 Pilot-operated, reductor/alivio de presión módulo principal con cavidad de control T-8A integral
- PPHC Controlado por aire, pilot-operated, reductor/alivio de presión válvula
- PPHF Pilot-operated, reductor/alivio de presión válvula con orificio de pistón barrenado
- PPHF8 Pilot-operated, reductor/alivio de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
- PRHB Acción-directa , reductor/alivio de presión válvula
- PRHR Acción-directa , reductor de presión válvula
- RSHC Pilot-operated, pistón balanceado secuencia válvula
- RSHC8 Pilot-operated, pistón balanceado secuencia módulo principal con cavidad de control T-8A integral
- RSHE Controlado por aire, pilot-operated, pistón balanceado secuencia válvula
- RVGA De venteo, pilot-operated, pistón balanceado alivio válvula
- RVGB Normalmente cerrado elementos de modulación válvula con función de alivio
- SCGA Acción-directa secuencia válvula con anti-retorno de caudal inverso
- SQHB Tirar-abajo, pilot-operated, pistón balanceado secuencia válvula
- XHBA Puerto 1 abierto al 3, puerto 2 bloqueado tapón de cavidad
- XHCA Todos los puertos bloqueados tapón de cavidad
- XHOA Puerto 1 abierto al 2, puerto 3 bloqueado tapón de cavidad
- XHOAE Puertos 1 y 2 al puerto externo, port 3 bloqueado tapón de cavidad
- XHOB Todos los puertos abiertos tapón de cavidad
- XHOC Cavidad T-17A a cavidad T-11A convertidor
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]
Technical Information