Serie 1 - cavidad T-11A, EPDM, cartucho juego de sellos
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- EPDM seals have no limited shelf life.
- EPDM seals are purple in color for easy stock and field identification.
Technical Data [ + ]
Series | 1 |
Cartridge Thread | M20M20 |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
cavidad | T-11A |
Cartridge Seal Installation Variations [ + ]
Cartridge Assignments | Models: CBCA, CSAB, LODO, RSDC, RVCA, SCCA, XEAA, Views: A,B,CModels: CBCA, CSAB, LODO, RSDC, RVCA, SCCA, XEAA, Views: A,B,C |
Cartridge Assignments | Models: CSAD, PBDB, PPDB, PPDL, PRDB, PRDC, PRDR, Views: A,B,DModels: CSAD, PBDB, PPDB, PPDL, PRDB, PRDC, PRDR, Views: A,B,D |
Cartridge Assignments | Models: XEOA, XEOB, Views: A,BModels: XEOA, XEOB, Views: A,B |
Used With [ + ]
What models can this kit be used with?
- CACG Proporción de pilotaje 5:1 , venteado (a) contrabalance válvula - de referencia atmosférica
- CBBC Proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
- CBBCX Ajuste fijo, proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
- CBBD Proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
- CBBDX Ajuste fijo, proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
- CBCA Proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
- CBCAX Ajuste fijo, proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
- CBCG Proporción de pilotaje 4.5:1 , capacidad estándar contrabalance válvula
- CBCH Proporción de pilotaje 10:1 , capacidad estándar contrabalance válvula
- CBCL Proporción de pilotaje 2.3:1 , capacidad estándar contrabalance válvula
- CKCB Anti-retorno con pilotaje para abrir válvula con piloto estándar
- CKCD Anti-retorno con pilotaje para abrir válvula con piloto sellado
- CODA Pilotaje para cerrar anti-retorno válvula
- CODD Proporción de 20:1, pilotaje para cerrar anti-retorno válvula
- CSAB Solo una esfera selector válvula con señal al puerto 3
- CSAD Solo una esfera selector válvula con señal al puerto 2
- LODD Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2
- LODD8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2 y cavidad de control T-8A integral
- LODO Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico
- LRDC Normalmente cerrado, elementos de modulación
- PBDB Pilot-operated, reductor de presión válvula
- PBDB8 Pilot-operated, reductor de presión módulo principal con cavidad de control T-8A integral
- PPDB Pilot-operated, reductor/alivio de presión válvula
- PPDB8 Pilot-operated, reductor/alivio de presión módulo principal con cavidad de control T-8A integral
- PPDL8 Pilot-operated, reductor/alivio de presión módulo principal con transición abierta y cavidad de control T-8A integral
- PRDB Acción-directa , reductor/alivio de presión válvula
- PRDC Acción-directa , reductor/alivio de presión válvula con transición abierta
- PRDR Acción-directa , reductor de presión válvula
- RSDC Pilot-operated, pistón balanceado secuencia válvula
- RSDC8 Pilot-operated, pistón balanceado secuencia módulo principal con cavidad de control T-8A integral
- RVCA De venteo, pilot-operated, pistón balanceado alivio válvula
- SCCA Acción-directa secuencia válvula con anti-retorno de caudal inverso
- XEAA Puerto 2 abierto al 3, puerto 1 bloqueado tapón de cavidad
- XEOA Puerto 1 abierto al 2, puerto 3 bloqueado tapón de cavidad
- XEOB Todos los puertos abiertos tapón de cavidad
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- See installation variations for models associated with alternative installation views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
Additional Resources [ + ]
Technical Information