Serie 1 - cavidad T-10A y cavidad T-13A, buna-N, cartucho juego de sellos

990010007 : Serie 1 - cavidad T-10A y cavidad T-13A, buna-N, cartucho juego de sellos
Technical Features [ + ]

Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
  • The Series 1, two port cavity comes in two versions: the T-10A and the T-13A. The T-10A cavity is typically used in relief applications which require larger port areas, hence a deeper cavity. The T-13A cavity is typically used in flow control applications and utilizes a smaller port area. Since both cavities are Series 1, two port, they share common seal kits, but exclude the possibility of cartridge interchangeability between the two functions.
Cartridge Installation Data [ + ]
Series 1
Cartridge Thread M20M20
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
cavidad T-10A
Cartridge Seal Installation Variations [ + ]
Cartridge Assignments Models: CDAA, CNCC, CSAA, CXCD, FCCB, FDBA, FQCA, FXCA, NCCB, NCCC, NCCD, RBAC, RBAT, RPEC, RPEE, RQEB, SCCB, SXCB, XFCA, XGAA, XGCA, Views: A,BModels: CDAA, CNCC, CSAA, CXCD, FCCB, FDBA, FQCA, FXCA, NCCB, NCCC, NCCD, RBAC, RBAT, RPEC, RPEE, RQEB, SCCB, SXCB, XFCA, XGAA, XGCA, Views: A,B
Cartridge Assignments Models: CDAC, CXDF, CNDB, CSAC, CNDC, CXDA, CXDB, FLDA, CXCB, XFAA, XFAB, Views: A,DModels: CDAC, CXDF, CNDB, CSAC, CNDC, CXDA, CXDB, FLDA, CXCB, XFAA, XFAB, Views: A,D
Cartridge Assignments Models: NFCC, NFCD, DLDB, Views: A,CModels: NFCC, NFCD, DLDB, Views: A,C
Used With [ + ]

What models can this kit be used with?

  • CDAA Espalda-con-espalda anti-retorno/selector válvula con señal externa
  • CDAC Espalda-con-espalda anti-retorno/selector válvula con señal al puerto 2
  • CNCC Fixed-orifice, no compensado por presión , control de caudal válvula con anti-retorno de caudal inverso
  • CNDC Caudal libre de nariz al lado anti-retorno válvula con orificio de desvió
  • CSAA Solo una esfera selector válvula con señal externa
  • CSAC Solo una esfera selector válvula con señal al puerto 2
  • CXCD Caudal libre del lado a la nariz anti-retorno válvula
  • CXDA Caudal libre de nariz al lado anti-retorno válvula
  • FCCB Fixed-orifice compensado por presión control de caudal válvula con anti-retorno de caudal inverso
  • FDBA Totalmente ajustable compensado por presión control de caudal válvula con anti-retorno de caudal inverso
  • FLDA Filtro
  • FQCA Fixed-orifice, fusible de caudal válvula
  • FXCA Fixed-orifice, compensado por presión control de caudal válvula
  • NCCB Totalmente ajustable aguja válvula con anti-retorno de caudal inverso
  • NCCC Totalmente ajustable aguja válvula con anti-retorno de caudal inverso
  • NCCD Totalmente ajustable aguja válvula con anti-retorno de caudal inverso
  • NFCC Totalmente ajustable aguja válvula
  • NFCD Totalmente ajustable aguja válvula
  • RBAC Acción-directa alivio válvula - capacidad de pilotaje
  • RPEC Pilot-operated, pistón balanceado alivio válvula
  • RPEC8 Pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral
  • RPEE Acción-rápida , pilot-operated, pistón balanceado alivio válvula
  • RQEB Tirar-abajo, pilot-operated, pistón balanceado alivio válvula
  • RVCK FLeX Series 2-stage, solenoid-operated ajustable alivio válvula , normally vented
  • RVCL FLeX Series 2-stage, solenoid-operated ajustable alivio válvula , energize to vent
  • RVCM FLeX Series 2-stage, solenoid-operated ajustable alivio válvula , energize to block
  • RVCN FLeX Series 2-stage, solenoid-operated ajustable alivio válvula , normally blocked
  • SXCB De referencia atmosférica , acción-directa secuencia válvula sin anti-retorno de caudal inverso
  • XFAA Cavidad T-10A a cavidad T-8A convertidor
  • XFAB Cavidad T-10A a cavidad T-8A convertidor con malla de filtro
  • XFCA Todos los puertos bloqueados tapón de cavidad
  • XFCAE Puerto 1 al puerto externo, port 2 bloqueado tapón de cavidad
  • XFOA Todos los puertos abiertos tapón de cavidad
  • XGAA Cavidad T-13A a cavidad T-8A convertidor
  • XGCA Todos los puertos bloqueados tapón de cavidad
  • XGCAE Puerto 1 al puerto externo, port 2 bloqueado tapón de cavidad
Notes [ + ]
  • Install back-up rings and O-rings as shown in views.
  • See installation variations for models associated with alternative installation views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]