Pilot-operated, pistón balanceado alivio válvula assembly

Symbols

Cartridge Technical Features [ + ]

Pilot-operated, balanced-piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150-micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cartridge Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-16A
Series 3
Capacity 100 gpm380 L/min.
Maximum Operating Pressure 5000 psi350 bar
Factory Pressure Settings Established at 4 gpm15 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 4 in³/min.@1000 psi65 cc/min.@70 bar
Response Time - Typical 10 ms10 ms
Adjustment - No. of CW Turns from Min. to Max. setting 55
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight 1.20 lb0,55 kg
Seal kit - Cartridge Buna: 990016007
Seal kit - Cartridge EPDM: 990016014
Seal kit - Cartridge Polyurethane: 990016002
Seal kit - Cartridge Viton: 990016006
Manifold Technical Data [ + ]
Body Type aplilablesaplilables
Interface ISO 08ISO 08
Body Features A to B and B to AA to B and B to A
Stack Height 3.44 in.87 mm
Open Cavities 22
cavidad T-16A
CAD Files [ + ]
Symbol File Formats
Click the link of the file format you want to download.
CAD File Formats
Click the link of the file format you want to download.
        Notes [ + ]
        • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
        Additional Resources [ + ]
        Realces
        Technical Tips
        Technical Information