« Back to Library PDF herunterladen

Proportional Valve Control - Load Sensing and Priority

In this example, a sequence valve RS*C, gives priority flow to circuits A1 & A2 before circuits B1 & B2 can be fed. Flow control for 2 users with load-sensing (LS) feedback to the pump is integrated into the proportional valve type FT*K.

  • Sequence valve: RS*C
  • Proportional valve with LS port: FT*K
  • Pressure compensator: LP*C

Benefits of this circuit arrangement:

  • The sequence valve RS*C ensures that flow to circuits A is satisfied before circuits B can be supplied.
  • The 3/3-way proportional valve FT*K with upstream restrictive pressure compensators LP*C can control motors or cylinders. The LP*C maintains a constant pressure drop across the FT*K of 200 psi which ensures steady flow control in the four legs.
« Back to Library