Frequently Asked Questions
Why is the minimum opening pressure (bias spring pressure) on pilot-operated FLeX cartridges lower than competitor product?
FLeX pilot-operated cartridges do not have a bias spring in their open state. These valves will shift with less than 5 psi differential. This results in pilot-operated shift performance with direct-acting minimum pressure operation.