Frequently Asked Questions
Where would I use a DR__ instead of a DP__?
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.