All ports blocked cavity plug
Capacity: |
Cavity: T-64A
Technical Features [ + ]
This cavity plug blocks all ports.
Technical Data [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity | T-64A |
Series | 4 |
Maximum Operating Pressure | 5000 psi350 bar |
Valve Hex Size | 1 5/8 in.41,3 mm |
Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
Seal kit - Cartridge | Buna: 990064007 |
Seal kit - Cartridge | Polyurethane: 990064002 |
Seal kit - Cartridge | Viton: 990064006 |
FAQs [ + ]
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.