Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series | 1 |
Cartridge Thread | M20M20 |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Cavity | T-13A |
Used With [ + ]
What models can this kit be used with?
- DFCB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DLDA2-way, solenoid-operated directional spool valve
- DLDAS2-way, soft shift, solenoid-operated directional spool valve
- DLDAZ2-way, solenoid-operated directional spool valve with position switch
- DLDF 2-way, solenoid-operated directional spool valve (740 Series)
- DLDM 2-way, manually operated, directional spool valve
- DTCA2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
- DTCAZ2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap and position switch
- DTCM 2-way, manually operated, directional poppet valve with overlap
- DTDA2-way, direct-acting, solenoid-operated directional blocking poppet valve
- DTDAS2-way, direct-acting, soft shift, solenoid-operated directional blocking poppet valve
- DTDF 2-way, direct-acting, solenoid-operated directional blocking poppet valve (740 Series)
- DTDM 2-way, manually operated, directional poppet valve
- FPCC Electro-proportional flow control valve - normally closed
- FPCH Electro-proportional flow control valve - normally open
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- See installation variations for models associated with alternative installation views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.