« Back to Library Télécharger le PDF

Regeneration - Continuous

Cylinders can extend with full pressure being exerted on piston side and rod end side at the same time. The reduced area (rod diameter) results in a lower force but a faster extension speed.
  • Pilot-to-close check valve:      CO*A-XEN
  • Check valve:                           CX*A;,CX*E
  • Pilot-to-open check valve:      CK*B
Benefits of this circuit arrangement:
  • Fig.1 shows fast extension of a cylinder by regeneration. The pilot-to-close CO*A valve allows oil to flow from the rod end side of the cylinder to join the pump flow on the piston side of the cylinder for fast cylinder extension.  For retraction of the cylinder, the CO*A is piloted closed and the pump oil flows into the rod end side of the cylinder.
  • Fig.2 shows an alternative lower cost circuit with regeneration. A larger capacity directional valve may be required.

Note: If the annulus area is very small due to a large rod diameter, the return flow from the full bore side of the cylinder may be larger. A larger directional control valve may be prevented by adding a pilot-to-open check valve as shown. 

« Back to Library