Fixed-orifice, Balance de pression 2 voies / 3 voies, priority flow control with relief assemblage

Function

Function for YRDR
Port Designators [ + ]
Modifiers Ports
A, A/S Ports EF & P: 1/4" NPTF; Ports CF & T: 1/4" NPTF; Gage Port: 1/4" NPTF;
B, B/S Ports EF & P: 3/8" NPTF; Ports CF & T: 3/8" NPTF; Gage Port: 1/4" NPTF;
C, C/S Ports EF & P: 1/2" NPTF; Ports CF & T: 3/8" NPTF; Gage Port: 1/4" NPTF;
I, I/S Ports EF & P: SAE 6; Ports CF & T: SAE 6; Gage Port: 1/4" NPTF;
J, J/S Ports EF & P: SAE 8; Ports CF & T: SAE 8; Gage Port: 1/4" NPTF;
K, K/S Ports EF & P: SAE 10; Ports CF & T: SAE 8; Gage Port: 1/4" NPTF;
T, T/S Ports EF & P: 1/4" BSPP; Ports CF & T: 1/4" BSPP; Gage Port: 1/4" BSPP;
U, U/S Ports EF & P: 3/8" BSPP; Ports CF & T: 3/8" BSPP; Gage Port: 1/4" BSPP;
V, V/S Ports EF & P: 1/2" BSPP; Ports CF & T: 3/8" BSPP; Gage Port: 1/4" BSPP;
Caractéristiques techniques [ + ]

Cet ensemble consiste en un régulateur de débit 3 voies à orifice fixe à débit prioritaire. Alimenté en débit depuis l'orifice P il satisfait le débit prioritaire à l'orifice CF. Si le débit d'alimentation dépasse le débit requis par le prioritaire, l'excédent est dérivé à l'orifice EF. Ce débit dérivé peut être utilisé pour alimenter un circuit secondaire. Le limiteur de pression protège le débit régulé contre les surpressions en dérivant le débit en excès vers l'orifice T.

  • Le débit doit être spécifié par le client. Le débit effectif aura une tolérance de +/- 10% autour du débit spécifié.
  • L'option de réglage permet de faire varier le réglage nominal d'usine de + ou – 25%. Pour augmenter tourner dans le sens horaire
  • Les deux débits, prioritaire et excédentaire, sont utilisables à la pression de travail du système.
  • La pression à l’orifice de by-pass (orifice EF) peut être supérieure à celle de l’orifice prioritaire (orifice CF).
  • Il n’y a pas de débit excédentaire tant que le débit prioritaire n’est pas satisfait.
  • Le gicleur à paroi mince minimise les variations de débit dues aux variations de viscosité.
Caractéristiques [ + ]
Type de Corps Montage en ligneMontage en ligne
Capacité 15 gpm60 L/min.
Gamme des Débits 0,2 à 50 gpm1 - 200 L/min.
Diamètre des Trous de Fixation 0,34 in.8.6 mm
Profondeur des Trous de Fixation TraversantTraversant
Nombre de Trous de Fixation 22
FAQs [ + ]

Il y a exactement 15 gouttes Sun dans un centimètre cube.

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Notes [ + ]
  • Important: La pression maximum du système doit être considérée avec une grande attention. La limite de pression maximum à laquelle le bloc peut être utilisé dépend de la matière du bloc, alors que le type et la dimension des orifices sont secondaires. Les blocs forés fabriqués en aluminium ne sont pas prévus pour des pressions supérieures à 210 bar (3000 psi), et ce quelles que soient les types et dimensions des orifices spécifiés.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Ressources Complémentaires [ + ]