Bidirectionnel , à action directe limiteur de pression Valve
The bi-directional, direct-acting relief cartridge is a normally closed, pressure-limiting valve used to protect hydraulic components from pressure transients. When the pressure differential between ports 1 and 2 exceeds the valve setting, the valve starts to open, throttling flow to limit the pressure rise, regardless of the direction.
- Capacity from port 1 to port 2 is 25 GPM (95 L/min). Flow from port 2 to port 1 is rated at 10 GPM (40 L/min).
- Recommended minimum setting is 1200 psi (85 bar). Note: At settings below 1200 psi (85 bar), the valve is rated for maximum transient flows of 25 GPM (95 L/min) only.
- La régulation s’effectuant à l’intérieur de la cartouche, ces valves sont insensibles à la plupart des problèmes associés à la cavitation, c’est-à-dire le bruit et l’érosion du bloc foré.
- Les joints de la vis de réglage subissent la pression du système ce qui s’signifie que cette valve ne peut être réglée qu’en l'absence de pression. La procédure de réglage est la suivante : Vérifier le tarage, couper la pression, régler la valve, vérifier à nouveau le tarage...
- Cette valve est relativement insensible aux variations de température de l’huile et à la pollution.
- Sélectionner une plage de réglage dans laquelle la pression de tarage désirée se situe dans la partie supérieure de la plage afin d'obtenir la meilleure répétabilité de la valve.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-10A |
Taille | 1 |
Capacité | 25 gpm95 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Tarage en usine établi à | 4 gpm15 L/min. |
Fuite Maximale à la Fermeture | 10 drops/min.0,7 cc/min. |
Temps de Réponse - Typique | 2 ms2 ms |
Fermeture | >85% of setting>85% of setting |
Hystérésis | ≤ 3 %≤ 3 % |
Adjustment - No. of CW Turns from Min. to Max. setting | 55 |
Dimensions du six pans de la valve | 7/8 in.22,2 mm |
Couple de serrage de la valve | 30 à 35 lbf ft41 - 47 Nm |
Poids du composant | 0,40 lb0,20 kg |
Brevet Américain # | 11,384,85711,384,857 |
Seal kit - Cartridge | Buna: 990310007 |
Seal kit - Cartridge | Viton: 990310006 |
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Maybe not. We build in a good amount of overlap in the kick-down reliefs to prevent false tripping. This means they are not as fast as our standard pilot operated reliefs. A direct-acting relief valve set just above the kick-down relief valve would be good insurance.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
One graphic example is on a portable grain auger for silos. When the farmer gets caught in the auger the kick-down relief trips and allows him to escape.
Pour les pressions de tarage les tolérances sont indiquées dans notre page Performances et Caractéristiques Générales. Un lien vers cette page se trouve également dans l’onglet Ressources Complémentaires de la page produit correspondante.
- La manette de réglage à trois branches est maintenant disponible chez Sun comme option standard
- Conseils Techniques pour les Limiteurs et les Régulateurs de Débit
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Sun Étend ses Solutions Anticorrosion
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Precise electro-proportional inverse relief valve
- Cartouches Sun avec joints EPDM
- Limiteurs de Pression Antichocs, de Type Piloté, à Clapet Équilibré
- Limiteurs de pression en cartouche RDDT/RDFT certifiés CE/TÜV
- 'Soft' Relief Eliminates Pressure Spikes
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- CavitySaver multi-function valves deliver single-cartridge solutions
- Sun présente ses valves 'hybrides'
- Limiteurs De Pression Pilotés, à clapet équilibré
- Encore Une Solution Optimisée par Sun Hydraulics !
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Réducteurs de Pression à 2 et 3 Voies (1 Mo)
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Cartouches: Matières Utilisées dans les Produits SUN
- Pressure Equipment Directive 2014/68/EU