2-port energy harvester Valve
Capacité: |
Cavité: T-16A
Caractéristiques techniques [ + ]
This valve is a 2 port cartridge designed to convert hydraulic power from your application into electrical power. The valve accepts flow from Port 1 to Port 2 and outputs a 3-phase AC voltage signal.
- Power cable with mating connector is required (not included).
- The valve exhibits up to 6 drops per hour of internal leakage into the electronics housing. The auxiliary drain port must be gravity fed and therefore remain at atmospheric pressure to prevent submersion of the electronics.
- Valve must be installed in an upright or horizontal orientation. When installed horizontally, the collar should be positioned so that the drain is oriented downward.
- This product can handle a maximum of 200 PSI (14 bar) at port 2 and is designed to harvest energy from fluid destined to return to tank.
- Higher electrical loads and lower Port 2 pressure have a positive effect in reducing leakage.
- In addition to elevated leakage, higher than rated pressures at Port 2 result in a reduction in the power output.
- The electrical output is unregulated. Most applications will require external rectification/regulation.
- Meets new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Zinc-nickel plating standard for 1000-hour salt fog protection.
- Only 3 pins of the Deutsch DT04-4P Connector are used. The 4th pin is unused. Please see pinout for reference.
- Do not apply installation torque to the anodized aluminum motor housing.
- This valve is CE compliant. It meets the requirements for RF Radiated Emissions (IEC 61000-6-4), Radiated Immunity (IEC 61000-4-3), and Magnetic Field Immunity (IEC 61000-4-8).
- When torquing this cartridge into its cavity, a crow’s foot wrench or similar will be required since the motor housing precludes the use of a deep socket wrench.
Caractéristiques [ + ]
Remarque: Les caractéristiques peuvent changer selon la configuration. Voir la section CONFIGURATION.
Cavité | T-16A |
Taille | 3 |
Number of Outputs | 11 |
Vibrations | 33.3 Hz 6.8g Peak (Spec: S-367 Section 11.0)33.3 Hz 6.8g Peak (Spec: S-367 Section 11.0) |
Choc | 49g Peak (Spec: S-367 Section 12.0)49g Peak (Spec: S-367 Section 12.0) |
Température Ambiante Maximum | 160 °F160 °F |
Minimum Flow Rate to Harvest Energy (No Load) | 10 gpm40 L/min. |
Maximum Flow Rate | 50 gpm200 L/min. |
External Drain Port Interface | 4mm PTC Connector4mm PTC Connector |
External Drain Port Leakage Rate | 6 drops/hr6 drops/hr |
Output Voltage - Maximum Flow Rate | 30 VDC (After Rectification)30 VDC (After Rectification) |
Termination | Deutsch DT04-4PDeutsch DT04-4P |
Maximum Load Current | 3A3A |
Maximum Operating Pressure (Port 2) | 200 psi14 bar |
Facteur de service | 100 %100 % |
Connecteur | 4-Pin Deutsch (3 Phase AC Output)4-Pin Deutsch (3 Phase AC Output) |
Dimensions du six pans de la valve | 1"1/4 in.31,8 mm |
Couple de serrage de la valve | 150 à 160 lbf ft203 - 217 Nm |
Poids du composant | 2,36 lb2,36 lb |
IP Rating | IP69KIP69K |
Seal kit - Cartridge | Viton: 990316006 |
Performance Curves [ + ]
FAQs [ + ]
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
The three phase AC output can be converted to DC with a full-wave bridge rectifier. The output voltage will be dependent on the flow rate.
Raw output from the Energen is both unregulated and unrectified. Power conditioning requirements will include rectification of the AC signal and voltage regulation to supply steady DC input to an electrical system. The specifics of power conditioning will depend on the requirements of your system. Sun can provide suggestions for a streamlined solution for 12 V systems. Please visit our tech tips for more information or contact tech support.
Ressources Complémentaires [ + ]
A la Une de Sun
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Encore Une Solution Optimisée par Sun Hydraulics !
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Sun Étend ses Solutions Anticorrosion
- Cartouches Sun avec joints EPDM
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
Informations et Conseils Techniques Pour les Differentes Fonctions Hydrauliques SUN
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Fonctions Spécifiques (462.31 Ko)
Technical Information
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- Performances et Caractéristiques Générales
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Cartouches: Matières Utilisées dans les Produits SUN