FLeX Series 4 voies , 2 Positions, électro distributeur à tiroir Valve - 3000 psi (210 bar)
Capacité: 4 gpm15 L/min. |
Cavité: T-30A
Caractéristiques techniques [ + ]
This FLeX Series solenoid-operated 4-way, 2-position cartridge is a direct-acting, balanced spool directional valve.
- Cette valve est à action directe et ne nécessite pas de minimum de pression hydraulique pour fonctionner.
- Designed and tested to 10-million operational cycles at full-rated pressure.
- Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Designed using CFD simulation for optimized geometries.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- Le noyau du solénoïde est à bain d’huile, ce qui signifie que le fluide du système, qui entoure le noyau, est soumis à la chaleur générée par la bobine. Il faut en tenir compte dans les cas où la bobine est excitée pendant une durée prolongée. Certains fluides, notamment les mélanges eau/glycol, se détériorent à ces températures et avec le temps, des vernis se forment et peuvent affecter le fonctionnement de la cartouche.
- Une large gamme d’options de connexions et de tensions d’alimentation des bobines est disponible, avec ou sans diode "Roue Libre" anti-self. Voir la section CONFIGURATION.
- Selon le type de connecteur, les bobines offrent une protection allant jusqu'à IP69K. Voir les fiches techniques des bobines pour de plus amples renseignements. Des bobines étanches et des kits d'étanchéité sont disponibles pour une protection supérieure en environnements difficiles.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Caractéristiques [ + ]
Remarque: Les caractéristiques peuvent changer selon la configuration. Voir la section CONFIGURATION.
Cavité | T-30A |
Taille | 0 |
Capacité | 4 gpm15 L/min. |
Pression maximale de fonctionnement | 3000 psi210 bar |
Typical Valve Leakage at 110 SUS (24 cSt) - Except N Spool | 2 in³/min.@3000 psi30 cc/min.@210 bar |
Typical Valve Leakage at 110 SUS (24 cSt) - N Spool, Inlet on 3 | 5 in³/min.@3000 psi80 cc/min.@210 bar |
Temps de Réponse - Typique | 50 ms50 ms |
Fréquence de commutation | 15,000 max. cycles/hr15,000 max. cycles/hr |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 3/4 in.19,1 mm |
Couple de serrage de la valve | 25 à 30 lbf ft35 - 40 Nm |
Poids du composant | 0,65 lb0,30 kg |
Seal kit - Cartridge | Buna: 990030007 |
Seal kit - Cartridge | Viton: 990030006 |
Seal and nut kit - Coil | Viton: 990740006 |
Performance Curves [ + ]
FAQs [ + ]
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Yes. All FLeX phase 1 valves are available in the SmartConnect schematic tool, and are also available for submittal to QuickDesign.
Yes. All FLeX valves utilize the Sun floating nose design.
Nominal flow capacity is based on performance limits. Maximum flow capacity is based on pressure drop. When selecting any direct-acting solenoid valve, first check the performance limits plot, then check if pressure drop is acceptable.
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
Ressources Complémentaires [ + ]
A la Une de Sun
- Conseils Techniques pour les Distributeurs Pilotés
- Sun Étend ses Solutions Anticorrosion
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Cartouches Sun avec joints EPDM
- Encore Une Solution Optimisée par Sun Hydraulics !
- Distributeurs à Commande Manuelle
- New FLeX Series Solenoid-Operated Directional Valves
- SUNs kleinste 2- und 3-Wege Druckminderventile bieten beste Eigenschaften auch bei kleinen Volumenströmen.
- Conseils Techniques pour les Distributeurs à Commande Électrique
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Distributeurs et Étrangleurs Proportionnels, à Commande Hydraulique
- Pourquoi attendre ? Obtenez Sun’s FLeX valves & nos nouveaux XMD modules quand vous les voulez.
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Nouvelles Électrovalves de Pilotage Sun
Informations et Conseils Techniques Pour les Differentes Fonctions Hydrauliques SUN
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Électrovalves (1.18 Mo)
- Distributeurs à Pilotage Externe (418.4 Ko)
- Distributeurs à Pilotage Interne (629.36 Ko)
Technical Information
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Performances et Caractéristiques Générales
- Cartouches: Matières Utilisées dans les Produits SUN
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
- 747 Series Hazardous Location Coils - CSA Certificate of Complian (106.22 Ko)
- 747 Series Hazardous Location Coils - IECEx Certificate of Confor (285.26 Ko)
- 747 Series Hazardous Location Coils - ATEX Certificate (976.94 Ko)
infos pour les Bobines [ + ]
No coil selected.