3 Voies, électro distributeur à tiroir Valve (740 Series)
Cette électrovalve en cartouche 3 voies / 2 positions est un distributeur à action directe à tiroir équilibré.
- L’ensemble du doigt de gant du solénoïde est dimensionné pour fonctionner à 350 bar, hors limite de fatigue.
- The R-spool is closed in the transition between its two positions. This results in a higher performance limit at the expense of lower capacity. When used as pilot controls, where capacity is not a factor, the closed transition will provide faster and more consistent response times.
- Cette valve est à action directe et ne nécessite pas de minimum de pression hydraulique pour fonctionner.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This cartridge utilizes both 740 Series high-power and 747 Series hazardous location coils.
- This cartridge has an option for manual override. See the CONFIGURATION section.
- Pour les modèles équipés du dispositif de contrôle D ou L, le mécanisme d'indexage présent dans la commande manuelle est destiné à des actionnements temporaires. Les commandes manuelles de secours D, L et T ont une espérance de vie mécanique de 7000 cycles environ.
- Le noyau du solénoïde est à bain d’huile, ce qui signifie que le fluide du système, qui entoure le noyau, est soumis à la chaleur générée par la bobine. Il faut en tenir compte dans les cas où la bobine est excitée pendant une durée prolongée. Certains fluides, notamment les mélanges eau/glycol, se détériorent à ces températures et avec le temps, des vernis se forment et peuvent affecter le fonctionnement de la cartouche.
- La conception unique de ce solénoïde assure une grande efficacité. La force de commande du tiroir par Watt utilisé est élevée et assure une bonne fiabilité de commutation de la valve.
- Coils can be mounted on the tube in either direction.
- Cette valve intègre le concept Sun de la cartouche à visser "flottante" qui permet de minimiser les contraintes internes dues à un couple de serrage excessif de la cartouche et/ou à des écarts d’usinage des cavités ou des cartouches.
Cavité | T-11A |
Taille | 1 |
Capacité | 12 gpm45 L/min. |
Pression maximale de fonctionnement | 5000 psi350 bar |
Fuite Maximale à 24 cSt (100 SUS) | 5 in³/min.@3000 psi80 cc/min.@210 bar |
Force Nécessaire pour la Commande Manuelle | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
Course de la Commande Manuelle | 0,1 in.2,5 mm |
Temps de Réponse - Typique | 50 ms50 ms |
Fréquence de commutation | 15,000 max. cycles/hr15,000 max. cycles/hr |
Diamètre du Doigt de Gant | 0,63 in.16 mm |
Dimensions du six pans de la valve | 7/8 in.22,2 mm |
Couple de serrage de la valve | 30 à 35 lbf ft41 - 47 Nm |
Poids du composant | 0,80 lb0,35 kg |
Seal kit - Cartridge | Buna: 990411007 |
Seal kit - Cartridge | Viton: 990411006 |
Seal and nut kit - Coil | Viton: 990740006 |
Il y a exactement 15 gouttes Sun dans un centimètre cube.
Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
- Il est nécessaire de vérifier l'encombrement des cartouches lorsque vous sélectionnez un bloc foré. Différents types de valves, de dispositifs de contrôle, et de bobines nécessitent des encombrements disponibles différents.
- Pour permettre l'installation ou le retrait de la bobine il est nécessaire de prévoir une hauteur libre dans le prolongement du tube magnétique d'au moins 50,8 mm (2.00 in).
- Get the relief you need. Adjustable. Ventable. Blockable. FLeX-ible.
- Conseils Techniques pour les Distributeurs à Commande Électrique
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- New FLeX Series Solenoid-Operated Directional Valves
- Distributeurs et Étrangleurs Proportionnels, à Commande Hydraulique
- Conseils Techniques pour les Distributeurs Pilotés
- Sun Étend ses Solutions Anticorrosion
- FLeX Series 3-way directional blocking poppet valves
- Nouvelle Séries Électrovannes & Bobines Sun FLeX ™
- Cartouches Sun avec joints EPDM
- Encore Une Solution Optimisée par Sun Hydraulics !
- Distributeurs à Commande Manuelle
- Nouvelles Électrovalves de Pilotage Sun
- Les cartouches de la taille 4 PLUS offrent un débit supérieur pour des pertes de charge inférieures
- When Pressure Rises, Sun is there to Offer Relief
- Nouveauté Sun : Électrovalves Étanches pour Environnements Difficiles
- Usiner les Cavités pour Cartouches Sun (521.84 Ko)
- Électrovalves (975.25 Ko)
- Électrovalves (1.18 Mo)
- Distributeurs à Pilotage Interne (629.36 Ko)
- Liste et Définition des Tailles de Cartouche et des Cavités SUN
- LES CARTOUCHES à VISSER SUN à “NEZ FLOTTANT” (447.56 Ko)
- Recommandations pour les Fluides et les Températures
- Units of Measure, Settings, and Conversions
- Cartouches: Matières Utilisées dans les Produits SUN
- Performances et Caractéristiques Générales
- Sun Model Code Explanation; 999-901-334 (343.9 Ko)
No coil selected.