Where should I mount pilot-to-open check valves in my system?
Frequently Asked Questions
Where should I mount pilot-to-open check valves in my system?
Generally, pilot-to-open check valves should be mounted as close to the actuator as possible to provide maximum protection in the event of hydraulic hose or line failure. Sun offers many mounting configurations that will accomplish this. Additionally, these cartridges can be installed directly in the actuator by machining a cavity in the actuator housing.