What do you mean by hysteresis when referring to a counterbalance valve?
Frequently Asked Questions
What do you mean by hysteresis when referring to a counterbalance valve?
Hysteresis is the difference between the pressure at which the valve will crack open and then reseat closed. Sun's counterbalance valve's hysteresis is typically less than 15%, which means the valve will have reseated to a closed position at 85% of its cracking or opening pressure.