740 Series operación de retener / trabar, activador manual juego de control, control L
The twist/lock manual override is a rotary, hand-actuated device for use on Sun's (full flow solenoid valves and FLeX series valves). The hand knob is constructed of a reinforced plastic for durability, heat resistance, and stability in varying environmental conditions and is suitable for operation with a gloved hand. The override assembly incorporates a sealed-construction design thereby preventing the introduction of debris and other damaging contamination. Once installed on a Sun solenoid valve, the override feature allows the operator to manually shift the de-energized valve. Solenoid cartridges may be ordered in this configuration by specifying a "L" control in the cartridge model number. Sun kits for field conversion are also available. Please note that valves with the twist/lock manual override are not suitable for load holding applications.
- The detent/lock override option "L" allows the operator to shift the valve into a mechanically detented position by twisting the manual override counter-clockwise. This detented position will be maintained until the operator twists the manual override clockwise and allows the valve to return to its de-energized position. Please note that the detented position is not suitable for load holding applications.
- The manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
- For proper operation of the twist-type manual overrides, it is important to grasp the cap fully before turning.
For Cartridge Models | DBAF, DFBD, DFBE, DFBF, DFBG, DLDF, DTAF, DTBF, DWBD, DWBF, DWDFDBAF, DFBD, DFBE, DFBF, DFBG, DLDF, DTAF, DTBF, DWBD, DWBF, DWDF |
Material | Black plastic and aluminumBlack plastic and aluminum |
Description | Detent/Lock Operation (Option L)Detent/Lock Operation (Option L) |
Operating Torque | 15 lbf in.15 lbf in. |
What models can this kit be used with?
- DBAF 3-vías direccional, operada por solenoide carrete válvula - capacidad de pilotaje (740 Series)
- DFBD FLeX Series 2-vías , 2-stage, direccional, operada por solenoide disco válvula con anti-retorno de caudal inverso - caudal 2-1, 3000 psi (210 bar)
- DFBE FLeX Series 2-vías , 2-stage, direccional, operada por solenoide disco válvula con anti-retorno de caudal inverso - caudal 2-1, 3000 psi (210 bar)
- DFBF FLeX Series 2-vías , 2-stage, direccional, operada por solenoide disco válvula con anti-retorno de caudal inverso - caudal 2-1
- DFBG FLeX Series 2-vías , 2-stage, direccional, operada por solenoide disco válvula con anti-retorno de caudal inverso - caudal 2-1
- DLDF 2-vías , direccional, operada por solenoide carrete válvula (740 Series)
- DTAF FLeX Series 2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula
- DTBF FLeX Series 2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula
- DTDF 2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula (740 Series)
- DWBF FLeX Series 3-vías, acción-directa , direccional, operada por solenoide blocking disco válvula
- DWDF 3-vías, acción-directa , direccional, operada por solenoide disco válvula (740 Series)
- Ensure o-ring is installed in bottom of the manual override assembly.
- Remove existing coil nut from end of solenoid tube.
- Thread the manual override assy on to the end of the solenoid tube. Point coil connector in desired position before hand tightening the manual override assy.
- Note: Thread lock may be used if anticipated conditions warrant.