Serie 1 - cavidad T-21A, EPDM, cartucho juego de sellos
Technical Features [ + ]
Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
- EPDM seals have no limited shelf life.
- EPDM seals are purple in color for easy stock and field identification.
Technical Data [ + ]
Series | 1 |
Cartridge Thread | M20M20 |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
cavidad | T-21A |
Cartridge Seal Installation Variations [ + ]
Cartridge Assignments | Models: DKDS, DODS, DPBP, HVCA8, Views: A,B,C,DModels: DKDS, DODS, DPBP, HVCA8, Views: A,B,C,D |
Cartridge Assignments | Models: FKBA, Views: A,B,C,EModels: FKBA, Views: A,B,C,E |
Used With [ + ]
What models can this kit be used with?
- CVCV Anti-retorno venteado con pilotaje para abrir válvula
- DKDS Normalmente cerrado, disco balanceado, elemento lógico - pilotaje para abrir
- DODS Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar
- DPBP 3-vías, pilot-operated, direccional válvula con drenaje al puerto 4 (1 a 2 abierto, 3 bloqueado)
- FKBA 2-vías , pilot-shifted, proporcional estrangulación
- HVCA8 De venteo, pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral - antes del anti-retorno
- PSDT Acción-directa , reductor/alivio de presión módulo principal fuente de pilotaje del puerto 4
- PVDA Pilot-operated, reductor/alivio de presión válvula con drenaje al puerto 4
- PVDB De venteo, pilot-operated, reductor/alivio de presión válvula
- RVCD De venteo, pilot-operated, pistón balanceado alivio válvula con drenaje al puerto 4
- RVCD8 De venteo, pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral y drenaje al puerto 4
Notes [ + ]
- Install back-up rings and O-rings as shown in views.
- See installation variations for models associated with alternative installation views.
- When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
- When installing cartridge - be sure to torque to recommended value.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
Additional Resources [ + ]
Technical Information